Инструкция для CARRIER 38VTA060, 38VTA050, 38VTA040, 42XQA060, 42XQA050, 42XQA040

(скачивание инструкции бесплатно)
Формат файла: PDF
Доступность: Бесплатно как и все руководства на сайте. Без регистрации и SMS.
Дополнительно: Чтение инструкции онлайн
background image

42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control)

42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)

®

OWNER’S MANUAL

42XQ/XQA

UNDERCEILING

CONSOLE

42XQ

42XQA

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Оглавление инструкции
  • Страница 1 из 29
    OWNER’S MANUAL 42XQ/XQA ® 42XQ UNDERCEILING CONSOLE 42XQA 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)
  • Страница 2 из 29
    Thank you for choosing Carrier! You can be sure that you’ve made a wise choice, because the same pride we take in manufacturing the Carrier equipment installed in the Astrodome in Texas, in the Sistine Chapel, in the Capitol – the seat of the US Congress – and in thousands of other installations
  • Страница 3 из 29
    CONTENTS PRECAUTIONS.................................................................................................. 3 Safety considerations 3 DISPLAYS OF THE INDOOR UNIT, LED INDICATORS & CONTROLS............ 6 Error codes 6 Emergency operation 7 REMOTE
  • Страница 4 из 29
    PRECAUTIONS Safety considerations The installation, servicing and maintenance of air conditioning equipment may be hazardous due to the pressure which the refrigerant gas exerts on the interior, and its electrical components. Only specialized and professionally qualified personnel may install,
  • Страница 5 из 29
    CAUTION DISCONNECTING THE UNIT FROM THE MAIN POWER SUPPLY These units must be connected to the main electrical power supply through a circuit-breaker or switch fuse with an appropriate capacity and with a minimum separation between the contacts of 3mm. If this is not possible, a contact/container
  • Страница 6 из 29
    4) Use only a circuit-breaker with a suitable capacity. Keep the unit away from heat sources. High temperatures may cause physical damage to the unit. 5) Do not obstruct the air discharge of any of the indoor and outdoor unit. Doing so, blocks the airflow, reducing the cooling capacity and causing
  • Страница 7 из 29
    DISPLAYS OF THE INDOOR UNIT, LED INDICATORS AND CONTROLS T S P R Q : : : : : EMERGENCY and RESET button Receiver of remote control signal Green LED Yellow LED Red LED NOTE Indoor Unit LEDs Information about the operating mode of the indoor unit is given by the 3 LEDs (light-emitting diodes) on the
  • Страница 8 из 29
    THE RED LED (Q) indicates the following information • During normal operation, the LED is switched off. During defrosting, the LED is illuminated. During the testing of the electrical connections, the LED flashes at 1 second intervals. • • THE YELLOW LED (R) indicates that the unit is operating in
  • Страница 9 из 29
    REMOTE CONTROL The remote control works with 1.5 V batteries. When the battery icon appears on the display of the remote control, it’s time to replace the old batteries. CAUTION Before replacing the batteries, the device must be disconnected. Inserting the batteries • Open the battery compartment
  • Страница 10 из 29
    NOTE • The maximum distance for the infrared remote control to work properly is 5 metres. • There must be no objects, for example, curtains, obstructing the space between the unit and the remote control. NOTE • Sunlight shinning directly onto the signal reception area of the unit may cause
  • Страница 11 из 29
    USING THE SELECTED FUNCTIONS 1. Operating mode (from left to right): 7. Low battery indicator • Ventilation (fan only) 8. Position of the air deflector • Cooling with dehumidification 9. Fan speed • Dehumidification only 10. Active customization 2. Signal transmission symbol 11. Timer ON selected
  • Страница 12 из 29
    USING THE WIRELESS REMOTE CONTROL Connect / Disconnect (Key B) Indicated symbol Ventilation (fan only) When the air conditioner is disconnected, the control display shows only the hour of the day (if other icons are shown, disconnect the control by pressing the “ ” button). Select the Operating
  • Страница 13 из 29
    Selecting the airflow direction (Key H) Selecting the fan speed (Key E) The deflector direction must be set so as to optimize the ambient airflow distribution. The fan speed can be selected by pressing the button with the icon. Press the button until one of the following positions is displayed:
  • Страница 14 из 29
    < < 2. HOUR and MINUTES buttons ( and buttons) If the unit is connected, the only possible selection is the time of starting operation. The unit operates with the selections shown on the display. < < < < < 3. HOUR and MINUTES buttons ( and buttons) If the unit is disconnected: select the operating
  • Страница 15 из 29
    Customization (Button G and F) and Daily timer (DAILY - button J) If you want to save a customized operating mode which you can reactive at any time, complete the following steps: 1. With the remote control connected or disconnected, press button and keep it pressed down for more than 5 seconds.
  • Страница 16 из 29
    If you want the daily operating mode to start at 5:30pm and stop at 10:30pm, proceed as follows: 1. Select timer ON for 5:30pm 2. Select timer OFF for 10:30pm 3. Press the button of the daily operating mode (Button ) Programming the night timer (SLEEP - button ) Press this button to set the night
  • Страница 17 из 29
    Setting the hour (Button N) CAUTION !!! 1. With the remote control connected or disconnected, press button . The air conditioner will not work if there are curtains, doors or other objects blocking the signal sent from the remote control to the unit. < < 2. The numbers of the hour start flashing.
  • Страница 18 из 29
    Control to the left and right Specifications If you want to set the direction of the air to the right or left, adjust the deflector by hand after opening the horizontal deflector. • Operating Modes: Off (disconnected), Cool (cooling), Dry (dehumidification), and Fan only (ventilation). • Fan
  • Страница 19 из 29
    Display the selected functions Control Powered Up All of the segments of the Remote Control Display must be powered up for five seconds. Information about the operating mode, fan speed, desired temperature and configuration must be read from the Microprocessor inside the Remote Control. If the
  • Страница 20 из 29
    SETTING THE OPERATING MODE COOL and DRY modes “MODE” button • ICON of the Operating Mode. • Ambient Temperature: if configured by canceling the temperature sensor of the ambient environment unit (operated by the environment controller); otherwise the temperature is selected by the user with the
  • Страница 21 из 29
    FAN ONLY mode “FAN” button FAN ONLY Operation with fan ventilation only Setting the fan speed. When the “FAN” button is pressed, the fan speed is changed. To reach the desired speed, the “FAN” speed button must be pressed and then released. Low, Medium, High or Auto. (up) “UP” and “DOWN” buttons
  • Страница 22 из 29
    Air Deflector Control Information about Filters • Keep the “FAN” button pressed down for 5 seconds. The selected air deflector setting is displayed. By pressing the “UP” and “DOWN” buttons, you can change the desired configuration of the air deflector. • Air Filters (optional) - Option 1:
  • Страница 23 из 29
    CARE AND MAINTENANCE Operating Conditions Prevention of freezing in the indoor unit The temperature ranges compatible with the unit are as follows: • MODE INDOORS OUTDOORS 21~32oC 21~46oC DEHUMIDIFICATION 17~32oC 12~46oC COOLING • When the unit is operating below or above these conditions for an
  • Страница 24 из 29
    PRACTICAL TIPS Optimal comfort with low consumption • If you know that your air conditioner will not be used for an extended period of time: Ensure that you maintain the temperature of your house within the comfort zone. • • When the unit is operating in cooling mode, prevent sunlight from entering
  • Страница 25 из 29
    Cleaning the Indoor Unit Cleaning the outdoor Unit • Always disconnect the main power supply before unit performing any cleaning work. • From time to time, clean the area around the outdoor unit and remove the waste that may have accumulated and could cause a reduction in air circulation. • Only
  • Страница 26 из 29
    PRACTICAL TIPS Maintenance and User Guide Cleaning washable cloth filters Cleaning the Filters To determine how often these filters should be washed, you should take 1 month of operation as the basic length of time between washings. • The cloth filters must be washed with water only. • Remove the
  • Страница 27 из 29
    Photocatalyzer Filters Installer’s Guide After finishing the installation and testing, explain the main points of this Manual to the user, giving special attention to the main operating modes of the air-conditioning equipment as stated below: • • • Clean these filters once every three months. Wash
  • Страница 28 из 29
    WARNING DO NOT SWITCH ON/OFF FROM MAIN POWER ISOLATING SWITCH OR WALL MOUNTED CONTACTOR. USE ONLY SWITCHES ON WIRELESS OR WIRED REMOTE CONTROL TO AVOID DAMAGE TO OUTDOOR COMPRESSOR. ® Carrier International Sdn. Bhd. Malaysia Carrier International Sdn. Bhd. (3385-T) Lot 4, Jalan P/6, 43650 Bandar
  • Страница 29 из 29