IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control

31

SIS Configuration and 

Control

The scaler can be configured and controlled with Extron Simple Instruction Set (SIS) 
commands when connected to a host computer or other device (such as a control system). 
Attach the host device to the rear panel RS-232 connector, the LAN port, or the front 
panel USB port. Commands can be entered using a Telnet application such as the Extron 
DataViewer, available at 

www.extron.com

 (see the DataViewer Help file for more details). 

This section describes SIS communication and control. Topics in this section include:

• 

Host and Scaler Communication

• 

SIS Overview

• 

Command and Response Tables

The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control (see  

RS-232 Connector

 on page 11).

Host and Scaler Communication

SIS commands consist of one or more characters per field. No special characters are 
required to begin or end a command sequence. When the scaler determines that a 
command is valid, it executes the command and sends a response to the host device. All 
responses from the scaler to the host end with a carriage return and a line feed (CR/LF = 

]

), 

indicating the end of the response character string (one or more characters).

Scaler-Initiated Messages

When a local event such as a front panel selection or adjustment takes place, the scaler 
responds by sending a message to the host. No response is required from the host. Example 
scaler-initiated messages are listed here.

• 

In

 

X!

 

All

]

 (where 

X!

 is the input number during an input switch).

• 

Reconfig

]

 The scaler sends this response when an input is switched or when a new 

signal is detected.

• 

HplgO

X@]

 The scaler sends this response when a hot plug event on output 

X@

 is 

detected.

Copyright Information

The copyright message is displayed upon connecting to a scaler via TCP/IP or Telnet or after 
a power cycle via RS-232 and depends on the scaler model.

]

 

© Copyright YYYY, Extron Electronics, IN1606, Vx.xx, 60-1081-01

Ddd, DD MMM YYYY HH:MM:SS

 

]

 (day, date, and time as in 

Fri, 17 Feb 2013 11:27:33

)

]

 

© Copyright YYYY, Extron Electronics, IN1608, Vx.xx, 60-1238-01

Ddd, DD MMM YYYY HH:MM:SS

 

]

 (day, date, and time as in 

Fri, 17 Feb 2013 11:27:33

)

]

 

© Copyright YYYY, Extron Electronics, IN1608 SA, Vx.xx, 60-1238-02

Ddd, DD MMM YYYY HH:MM:SS

 

]

 (day, date, and time as in 

Fri, 17 Feb 2013 11:27:33

)

]

 

© Copyright YYYY, Extron Electronics, IN1608 MA, Vx.xx, 60-1238-03

Ddd, DD MMM YYYY HH:MM:SS

 

]

 (day, date, and time as in 

Fri, 17 Feb 2013 11:27:33

)

Vx.xx

 is the firmware version number.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
Оглавление инструкции

Document Outline