iv. 

Secure the mounting plate (and switcher) to 
the base plate by aligning the two small tabs 
on the back of the mounting plate over the 
corresponding tabs on the base plate (see 
figure at right). Slide the mounting plate (and 
switcher) down into place. Secure it to the 
base plate by passing a 6-32x¼ inch screw up 
through the securing tab (see figure at right). 
Tighten down the screw.

C3. Run the Cables to the USFM 100 Lcation.

Run signal cables from the PoleVault input 
wallplates, control device location, and the speakers 
to the USFM 100 location. Cables can be routed 
behind the walls, through a surface raceway (such 
as Wiremold 700 or 2400), or through conduit 
directly to the USFM 100.

If running cable behind the walls:

Run all the cables from all the locations to the USFM 
100 and through the access hole (cut in step C1d). 

If using a surface raceway or conduit:

i. 

Turn over the left or right cover as needed, and 
from the inside, cut the most suitable marked 
raceway or conduit knockout for the cable to 
enter the USFM 100. Remove the knockout.

ii. 

Run the raceway or conduit from all locations 
to the marked entrance and attach to the 
baseplate.

(1) 6-32 x 1/4"
Screw

(2) 4-40 x 1/4"
 Screws 

Mounting Plate

PVS 405D
Switcher

Securing
Tab

USFM 100 Base Plate

32 

(1) 6-3

w

Screw

S 4055D

tcherr

Tab

L

R

DO 

NOT

GROU

ND

OR 

SH

OR

T

SPE

AK

ER

OU

TPU

TS

4/8

Ω

3A

 MA

X

POW

ER

12V

HD

MI

1/2

SIG

LIN

K

SIG

LIN

K

3/4

INP

UT

S

OU

TP

UT

AU

DIO

 O

UT

PVS

 40

5SA 

IP

AMP

LIFIE

D AU

DIO

 O

UT

PAG

ING

SE

NSO

R

PV

T IN

PV

T IN

L

R

AU

X

OVE

R P

VT

RE

MO

TE

VO

ICE

LIFT

LA

N 1

LAN

 2

LAN

 3

IN

PU

T 5

+V

L

R

RS

-232

Tx

Rx

IR

S

G

G

Mounting the Switcher onto the Base Plate. 

Signal Cable Access
Cutout Option

2400

V700

Raceway Option

Conduit Option

Options for Running the Cables to the USFM 100

PoleVault Digital Systems • Installation — Stage 4 (USFM 100 and PVS 405D)

49

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
Оглавление инструкции

Document Outline