This instruction manual is for the Olympus Biological Microscope Model CX31. To ensure
the safety, obtain optimum performance and to familiarize yourself fully with the use of this
microscope, we recommend that you study this manual thoroughly before operating the
microscope. Retain this instruction manual in an easily accessible place near the work
desk for future reference.

Оглавление инструкции
  • Страница 1 из 24
    INSTRUCTIONS CX31 BIOLOGICAL MICROSCOPE This instruction manual is for the Olympus Biological Microscope Model CX31. To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of this microscope, we recommend that you study this manual thoroughly before
  • Страница 2 из 24
    CX31 CONTENTS Page IMPORTANT — Be sure to read this section for safe use of the equipment. — 1-3 1 NOMENCLATURE 4 2 SUMMARY OF BRIGHTFIELD OBSERVATION PROCEDURE 5 3 ASSEMBLY 4 USING THE CONTROLS — See this section for the replacement of the light bulb. — 6-7 8-14 4-1
  • Страница 3 из 24
    IMPORTANT SAFETY PRECAUTIONS Fig.1 1 1. After the equipment has been used in an observation of a specimen that is accompanied with a potential of infection, clean the parts coming in contact with the specimen to prevent infection. · Moving this product is accompanied with the risk of dropping the
  • Страница 4 из 24
    CX31 Safety Symbols The following symbols are found on the microscope. Study the meaning of the symbols and always use the equipment in the safest possible manner. Symbol Explanation Indicates that the surface becomes hot, and should not be touched with bare hands. Before use, carefully read the
  • Страница 5 из 24
    1 Maintenance and Storage 1. Clean all glass components by wiping gently with gauze. To remove fingerprints or oil smudges, wipe with gauze slightly moistened with a mixture of ether (70%) and alcohol (30%). Since solvents such as ether and alcohol are highly flammable, they must be handled
  • Страница 6 из 24
    CX31 NOMENCLATURE }The revolving nosepiece is fastened with a band to prevent it from turning during transportation. Remove the band when unpacking the microscope. Be sure to store the band for re-transportation of the microscope. * The stage is shipped with the two transport pins locked. When
  • Страница 7 из 24
    SUMMARY OF BRIGHTFIELD OBSERVATION PROCEDURE 1 · Turn the revolving nosepiece to engage the 10X objective. #Make sure that the revolving nosepiece stops with an audible click. 2 · Place a specimen on the stage. (Page 10) 4 · Set the main switch to “ I ” (ON) and adjust the brightness with the light
  • Страница 8 из 24
    CX31 ASSEMBLY 1 Mounting the Bulb (Replacement of Bulb) (Fig. 3) 1. Turn the microscope frame on its side and pull the lamp housing knob @ on the underside of the base to open the lamp housing cover. 2. Holding the halogen bulb ² contained in the polyethylene bag to avoid leaving fingerprints on
  • Страница 9 из 24
    3 Fig. 7 Attaching the Optional Cord Hanger (CH3-CH) (Figs. 7 & 8) }By attaching the optional CH3-CH cord hanger on the rear of the microscope frame, the power cord can be accommodated by winding around the hanger. Insert the hook ² of the cord hanger @ into the air vent groove on the rear of the
  • Страница 10 из 24
    CX31 USING THE CONTROLS 4-1 Base 1 Turning On the Bulb (Fig. 9) 1. Set the main switch @ to “ ” (ON). 2. Turn the light intensity knob ² clockwise in the direction of the arrow to make the illumination brighter or counterclockwise to make it darker. The numbers around the knob indicates the
  • Страница 11 из 24
    4-2 Focusing Block 1 2 DOWN UP 9 (Fig. 11) 1. The coarse adjustment knob tension is preadjusted for easy use. However, if desired, one can change the tension using the tension adjustment ring @. Applying a large flat-bladed screwdriver to any of the grooves ² on the circumference of the ring,
  • Страница 12 из 24
    CX31 4-3 Stage 1 Placing the Specimen (Fig. 13) #Releasing the curved finger with great force or suddenly releasing your grip on the curved finger knob @ while releasing the curved finger will crack or damage the slide glass. Always place the specimen with great care. Observation with Specimen
  • Страница 13 из 24
    2 Moving the Specimen (Fig. 14) Turn the upper knob which is the Y-axis knob @ to move the specimen in the vertical direction, and turn the lower knob which is the X-axis knob ² to move it in the horizontal direction. #Do not use the specimen holder or stage to move the specimen, for this will
  • Страница 14 из 24
    CX31 4 Using the Eye Shades (Fig. 18) When Wearing Eyeglasses Use with the eye shades in the normal, folded-down position. This will prevent the eyeglasses from contacting and scratching the eyepieces. When Not Wearing Eyeglasses Extend the folded eye shades in the direction of the arrow for
  • Страница 15 из 24
    4-5 Condenser 1 Centering the Field Iris Diaphragm (Figs. 21 & 22) 1. With the 10X objective engaged and the specimen brought into focus, turn the field iris diaphragm ring @ counterclockwise to stop down the diaphragm to near its minimum size. 2. Turn the condenser height adjustment knob ² to
  • Страница 16 из 24
    CX31 4-6 Immersion Objectives 1 Fig. 24 Using the Immersion Objectives (Fig. 24) }The 100X objective is included only in the standard set of the CX31RBSFA combination. #Be sure to use the provided Olympus immersion oil. When the oil of other make is used the surface of the Top lens of Condenser may
  • Страница 17 из 24
    TROUBLESHOOTING GUIDE Under certain conditions, performance of the unit may be adversely affected by factors other than defects. If problems occur, please review the following list and take remedial action as needed. If you cannot solve the problem after checking the entire list, please contact
  • Страница 18 из 24
    CX31 Problem Cause Remedy Page 2. Coarse/Fine Focus Adjustment a) Coarse adjustment knob is hard to turn. Tension adjustment overtightened. ring b) Stage drifts down by itself or focus is lost during observation. Tension adjustment ring is too loose. Tighten it. c) Coarse adjustment will not go all
  • Страница 19 из 24
    SPECIFICATIONS Item Specification 1. Optical system UIS (Universal Infinity System) optical system 2. Illumination Illuminator built in. 6V 30W halogen bulb (PHILIPS 5761) (Average service time: Approximately 100 hr. when used as directed) 100-120 V/220-240 V , 0.85/0.45 A, 50/60 Hz 3. Focusing
  • Страница 20 из 24
    CX31 OPTICAL CHARACTERISTICS Magnification The following table shows the optical characteristics of combinations of eyepieces and objectives. The figure on the right shows the performance data engraved on the objectives. Objective designation Mechanical tube length Numerical aperture Cover glass
  • Страница 21 из 24
    PROPER SELECTION OF THE POWER SUPPLY CORD If no power supply cord is provided, please select the proper power supply cord for the equipment by referring to “Specifications" and "Certified Cord" below. CAUTION : In case you use a non-approved power supply cord for Olympus products, Olympus can no
  • Страница 22 из 24
    CX31 Table 2 HAR Flexible Cord APPROVAL ORGANIZATIONS AND CORDAGE HARMONIZATION MARKING METHODS Approval Organization Printed or Embossed Harmonization Marking (May be located on jacket or insulation of internal wiring) Alternative Marking Utilizing Black-Red-Yellow Thred (Length of color section
  • Страница 23 из 24
    Shinjuku Monolith, 3-1, Nishi Shinjuku 2-chome, Shinjuku-ku, Tokyo, Japan EC REP Wendenstraße 14-18, 20097 Hamburg, Germany 3500 Corporate Parkway, P.O. Box 610, Center Valley, PA 18034-0610, U.S.A. One Corporate Drive, Orangeburg, NY 10962, U.S.A. 491B River Valley Road, #12-01/04 Valley Point
  • Страница 24 из 24