Tube Amplifier Output Transformers 

LL1620 , LL1623, LL1627, LL9202 

 
The LL1620, LL1623, LL1627 and LL9202 are output transformers for tube amplifiers. All transformers are based on the 
same core size, winding structure and secondaries, but differ in number of turns (and thus impedance level) of primaries.  
The transformers are highly sectioned with harmonically sized sections, which results in a minimum leakage inductance. 
This, combined with a low capacitance coil winding technique results in a wide frequency range.  
The transformers have a special audio C-core of our own production, which is gapped for desired DC current.  
The transformers are of open frame type suitable for mounting inside an amplifier housing. 

 

Physical dimensions, pin and mounting hole layout for LL1620, LL1627 (all dimensions in mm) 

 

 
 

Physical dimensions, pin and mounting hole layout for LL1623, LL9202 (all dimensions in mm) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

R031020 

Secondary connections

 

Bottom view

 

Primary connections

 

26

 

25

 

24

 

23

 

22

 

21

 

20

 

19

 

18

 

17

 

16

 

15

 

14

 

13

 

12

 

11

 

4 x M4  

Mounting holes 

110

 

53

 

90

 

78 

 

85 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

Secondary connections

 

Bottom view

 

Primary connections

 

3

 

1

 

2

 

4

 

7

 

5

 

6

 

8

 

26

 

25

 

24

 

23

 

22

 

21

 

20

 

19

 

18

 

17

 

16

 

15

 

14

 

13

 

12

 

11

 

4 x M4  

Mounting holes 

110

 

53

 

90

 

78 

 

85 

 

LUNDAHL

 

TRANSFORMERS

 

Tibeliusgatan 7 

 

International 

Domestic 

S-761 50 NORRTÄLJE 

Phone 

+46 - 176 13930 

0176-13930 

SWEDEN 

 

Fax 

+46 - 176 13935 

0176-13935 

 

1
2
3
4
Оглавление инструкции
  • Страница 1 из 5
    Tibeliusgatan 7 S-761 50 NORRTÄLJE SWEDEN LUNDAHL TRANSFORMERS Phone Fax International +46 - 176 13930 +46 - 176 13935 Domestic 0176-13930 0176-13935 Tube Amplifier Output Transformers LL1620 , LL1623, LL1627, LL9202 The LL1620, LL1623, LL1627 and LL9202 are output transformers for tube amplifiers.
  • Страница 2 из 5
    Pin spacing module: Weight: 5.08 mm (0.2") 2.5 kg Winding schematics: Coil 1 14 3 1 22 13 Coil 2 4 21 « outer 20 2 12 11 19 23 6 8 15 16 inner » 5 24 « inner 25 17 7 26 18 outer » The inner windings have a lower copper resistance due to smaller circumference LL9202 LL1620 LL1623 LL1627 4 x 26.5 : 8
  • Страница 3 из 5
    Electrical characteristics Primary Load Impedance, Primary DC Current Secondary connection for 4/8/16 Ω (See next page) -/B/C B/C/D C/D/E Core Air-gap and Maximum Output Power Core Airgap (Delta/2) 25 µ (Push-Pull) Primary Load Impedance (transformer copper resistance included) LL1627 2.3 kΩ 1.2 kΩ
  • Страница 4 из 5
    Primary Connections Indicates phase LL1620, LL1627 Primary connection for push-pull output stage Tube Anode V+ LL1620, LL1627 Primary connection for single-end output stage Tube Anode 4 5 6 4 Tube Anode 7 8 V+ Secondary connections Indicates phase A 11 V .05 Ω 5V 1 V+ 19 20 21 22 11 12 13 14 23 24
  • Страница 5 из 5