Инструкция для Lundahl LL1936

(скачивание инструкции бесплатно)
Формат файла: PDF
Доступность: Бесплатно как и все руководства на сайте. Без регистрации и SMS.
Дополнительно: Чтение инструкции онлайн
background image

LUNDAHL

 

 

TRANSFORMERS

 

Tibeliusgatan 7 

 

International 

Domestic 

SE-761 50 NORRTÄLJE 

Phone 

+46 - 176 13930 

0176-13930 

SWEDEN 

 

Fax 

+46 - 176 13935 

0176-13935 

 

Microphone Input Transformer  

LL1936 

 

The LL1936 is a microphone input transformer which can be connected for microphones with different 
impedance. It is built using our dual coil structure, with a mu metal lamination core. The transformer is 
magnetically shielded by a mu metal housing. 
 

Turns ratio:  

 

 

 

 

 

 

(

2+1) + (2+1) : 4 + 4 

Dims (Length x Width x Height above PCB (mm)): 

 

48 x 29 x 20

 

Pin layout 

 (viewed from component side) 

and winding schematics: 

 
 

5

 

 

 

 

 

 

  18 

 

  9  

13 

 

 

 

4

 

 

 

 

 

 

  17 

 

 

 

 

 

 

 

 

 

 

 

LL1936 

 

 

  16 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

  15 

 

  6  

10 

 

 

 

1

 

 

 

 

 

 

  14 

 
 
 
 
 
 
 
 
 
 

0.1 “ 

0.2 “ 

5

 

 
Weight:

 

90 g 

Rec. PCB hole diameter: 

1.5 mm

 

 

Secondary  connection  

Out+ 

Out- 

Connect (= Output centertap) 

for 1200 

Ω

 real or virtual 

impedance 

17 

14 

10 + 13 

 

Input impedance 

(1200 ohm load) 

Turns ratio 

 

In+ In- 

Connect 

Faraday 

shield 

and housing 

75 

Ω

 

2 : 8 

5 + 6 

9 + 2 

 

15 + 18 

150 

Ω

 

3 : 8 

5 + 1 

4 + 2 

 

15 + 18 

300 

Ω

 

4 : 8 

9 + 6 

15 + 18 

600 

Ω

 

6 : 8 

4 + 1 

15 + 18 

 
Static resistance of each primary 1 

(9-4 or 1-6):

 

13 

Ω

 

Static resistance of each primary 2 

(5-9 or 6-2):

 

24 

Ω

 

Static resistance of each secondary

:

 

50 

Ω

 

Distortion

   

Source 600 

Ω

, primary connection for 600 

Ω

  

0.1% THD @10dBU, 50Hz 

1% THD @ 20dBU, 50Hz 

Frequency response: 

Balanced input, 0 dBU signal level, source 600

Ω

 , load 10k

Ω

 

10Hz – 100kHz +/- 1dB rel. 1kHz 

Isolation between primary and secondary windings/ 
between windings and shield: 

4kV / 2kV 

 

 
 
 

 

 

 

 

 

 

 

R090907 

 17

 

  10

 

 

 

 13

 

 14

 

  15+18 & core+can

9

 

4

 

1

 

6

 

2

 

0.1 “ 

1.3” 

1.4” 

1
Оглавление инструкции
  • Страница 1 из 2
    Tibeliusgatan 7 SE-761 50 NORRTÄLJE SWEDEN LUNDAHL TRANSFORMERS International +46 - 176 13930 +46 - 176 13935 Phone Fax Domestic 0176-13930 0176-13935 Microphone Input Transformer LL1936 The LL1936 is a microphone input transformer which can be connected for microphones with different impedance. It
  • Страница 2 из 2