ULTRASHIP Owners Manual & Troubleshooting Guide 

Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of Ultraship 
malfunction and inaccuracy

! We test all of our scale returns from consumers. Fully 60% of consumer 

returns are battery related problems. This sounds silly but it's true! A scale will perform slowly, or read 
inaccurately when it has low batteries. Please replace the batteries often (and only use good quality 
batteries). We include good quality batteries with all of our scales but batteries can run low in storage. If 
your scale simply won't turn on while on Battery power, this is often caused by loose battery 
connections. Battery prongs (terminals) are made of metal. They must be making good contact with 
your batteries in order for the scale to power on. You can use a paperclip to slightly bend the battery 
prongs to make them have a better connection. Also some poorly designed batteries have recessed or 
partially obstructed battery terminals. This may cause your prongs to be touching the plastic housing of 
the battery instead of the metal battery terminal. A Faulty AC adaptor can cause your scale to act 
unstable with numbers "jumping" all around. Please test your scale with a good set of batteries (instead 
of the AC adaptor) to determine if perhaps the AC adaptor is faulty. 

Some Ultra-75 scales will need a 

different or improved AC adaptor then the Ultra-50 and Ultra-30. You will know if you have this 
problem because the scale will power on but the numbers will fluctuate ("bounce" all around).

 Most 

Ultraship 75's do not have this problem, it's only happened a few times and it was caused by a slightly 
underpowered AC Adaptor (the output was slightly less then normal). The Ultra 75 requires just a bit 
more power then the Ultra 30, 35, 50 or 55 and thus is the only model affected by an AC adaptor that is 
giving a slightly less then normal output.  

IMPORTANT MANUAL CORRECTION: 2005/2006 Model Notes:

 During production we sometimes 

modify the Ultraship slightly to make it easier to use and perform more stable. This can cause some 
typos in the manual. Note that on the newest Ultraships there is 

NO STABLE INDICATOR,

 we removed it 

on some models as it was causing a software conflict. The 

BEEP

 function was also removed due to 

customer complaints.  

   

TROUBLESHOOTING & OPERATION NOTES  

1) If the scale does not perform accurately, please recalibrate as outlined in the manual.  

2) If the Display ever becomes locked on EEEEE, this indicates that the scale was shocked, dropped or 
otherwise damaged and the delicate weighing sensors have been damaged. You can try recalibrating the 
scale (If the sensor has not been hurt too badly it may work again after recalibration). Otherwise you will 
have to follow the warranty instructions that came with your scale.  

3) If the display becomes locked on 8888, this often indicates low power. However sometimes it also 
may indicate a serious zero mark error. This means when you turn the scale on, it can't determine what 

1
2
3
4
Оглавление инструкции
  • Страница 1 из 5
    ULTRASHIP Owners Manual & Troubleshooting Guide Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of Ultraship malfunction and inaccuracy! We test all of our scale returns from consumers. Fully 60% of consumer returns are battery related problems. This sounds silly but
  • Страница 2 из 5
    zero is (a slight zero mark error will cause situation #1 above) Thus, if new batteries do not fix this error please follow the warranty instructions. 4) If the display shows UNST, this means the scale is not stable. Try operating the scale on a more stable surface & be sure nothing is on the tray
  • Страница 3 из 5
    CAUTION Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction. Replace all batteries at the same time – Do not replace only a portion of the 4 batteries as this may cause a malfunction. If the scale is not to be used for a long period of time, remove all batteries
  • Страница 4 из 5
    Cell-Phones, Cordless-Phones, and any radio-frequency device can cause temporary interference and cause the scale to temporarily not work properly. Please do not use any electronic device near the scale. Just like in an Airplane, do not use your cell-phone near the scale when it is in use. While
  • Страница 5 из 5