Инструкция для VITEK VT-3531 SR

(скачивание инструкции бесплатно)
Формат файла: PDF
Доступность: Бесплатно как и все руководства на сайте. Без регистрации и SMS.
Дополнительно: Чтение инструкции онлайн
background image

WIRELESS WEATHER STATION 

The  weather  station  is  intended  for  temperature  and 

relative  humidity  level  measurement.  Use  the  main  unit 

to measure indoor parameters and the remote sensor for 

outdoor  or  indoor  measurement.  Besides,  the  unit  dis-

plays current time and date and has a built-in alarm clock.

DESCRIPTION

Main unit

1. 

«MAX/MIN» button

2. 

«

» button

3. 

«SNOOZE-LIGHT» button

4. 

«ALARM» button

5. 

«

» button

6. 

«SET» button

7. 

Sensor wall mounting hole

8. 

Battery compartment lid

9. 

Flap stand

Display

10. 

Remote temperature sensor indication «OUTDOOR»

11. 

Integrated temperature and humidity sensor  

indication «INDOOR»

12. 

Current time indication 

Remote sensor

13. 

Sensor

14. 

Display 

15. 

Sensor wall mounting hole

16. 

Temperature measurement unit selection buttons 

«°C/°F»

17. 

Battery compartment lid 

18. 

Stand

19. 

Wired temperature sensor

SAFETY MEASURES

Before using the unit, read this instruction manual care-

fully and keep it for future reference.

Use  the  unit  for  intended  purposes  only,  as  specified 

in  this  manual.  Mishandling  the  unit  can  lead  to  its 

breakage  and  cause  harm  to  the  user  or  damage  to 

his/her property. 

• 

Do not subject the unit to impacts (dust and mois-

ture are also to be avoided), as it can lead to failures, 

reduction  of  service  life,  battery  damage  and  to 

deformation of the unit body parts.

• 

Provide  that  no  liquid  gets  inside  the  unit  body. 

To  prevent  the  unit’s  damage,  do  not  expose  it  to 

rain  or  moisture,  do  not  place  the  unit  in  places 

with high humidity (near bathtubs, containers filled 

with water, kitchen sinks, washing machines, near a 

swimming pool, in wet basements, etc.). Protect the 

unit from dripping and splashing.

• 

The  unit  should  not  be  placed  near  heat  sources 

such  as  radiators,  electric  heaters,  stoves,  or  in 

places  exposed  to  direct  sunlight,  excessive  dust, 

vibration or mechanical shocks.

• 

Install the unit on flat stable surface in places with 

proper  ventilation.  Do  not  block  the  unit  ventila-

tion openings.

• 

Make sure that the wired sensor is not bent or pinched.

• 

Do not let foreign objects get into the unit openings.

• 

Do not repair the unit or make any changes in it by 

yourself. If you find any damages, switch the unit off 

by removing the batteries from the battery compart-

ment and apply to the authorized service center.

• 

If  you  disassemble  the  unit,  it  will  lead  to  warranty 

cancellation.  No  parts  inside  the  unit  require  the 

user’s attention.

• 

This unit is not intended for usage by children under 

8 years of age. 

• 

Children  aged  8  and  over  as  well  as  disabled  per-

sons  can  use  this  unit  only  under  supervision  of  a 

person  who  is  responsible  for  their  safety,  if  they 

are  given  all  the  necessary  and  understandable 

instructions  concerning  the  safe  usage  of  the  unit 

and  information  about  danger  that  can  be  caused 

by its improper usage.

• 

Do  not  leave  children  unattended  to  prevent  using 

the unit as a toy.

• 

For children safety reasons, do not leave polyethyl-

ene bags used as packaging unattended. 

Attention! Do not allow children to play with polyethyl-

ene bags or packaging film. Danger of suffocation!

• 

Do not disassemble the unit by yourself, if any mal-

function is detected or after the unit was dropped, 

apply to the nearest authorized service center.

• 

Do not use abrasives or substances causing dam-

ages  of  the  body  and  the  inner  parts  of  the  units 

for cleaning.

• 

Transport the unit in the original package only.

• 

Keep the unit out of reach of children and disabled 

persons.

THE  UNIT  IS  INTENDED  FOR  HOUSEHOLD  USAGE 

ONLY 

BEFORE THE FIRST USE

After unit transportation or storage under cold (win-

ter) conditions, it is necessary to keep it for at least 

two hours at room temperature before switching on.

– 

Unpack the unit, remove any stickers that can pre-

vent unit operation.

– 

Check the unit for damages. In case of damages do 

not switch the unit on.

BATTERY INSTALLATION

Attention! 

Batteries  leakage  can  cause  injuries  or  the  unit  dam-

age.  To  avoid  damages,  follow  the  recommendations 

specified below:

• 

insert batteries following the polarity;

• 

use only new batteries of the type specified in the 

instruction manual;

• 

do not insert batteries of different types, new bat-

teries with old ones, batteries of different brands as 

well as rechargeable batteries of different capacity;

• 

remove the batteries if you are not planning to use 

the unit for a long time;

• 

do not dismantle the batteries, do not subject them 

to high temperatures;

• 

replace the batteries in time.

Notes: 

• 

If  the  batteries  are  already  installed  into  the 

battery compartment, you need to remove the 

isolation insert.

• 

Long  operation  under  low  or  high  temperatures 

can reduce the voltage of the batteries of the sen-

sor (13), thus decreasing the transmission range.

• 

If  the  symbols’  contrast  on  the  display  has  signifi-

cantly reduced, replace the batteries. 

Remote sensor

– 

Shift  the  battery  compartment  lid  (17).  Insert  two 

“AAA”  batteries  (included),  strictly  following  the 

polarity. 

– 

Select  the  temperature  measurement  units  by 

pressing  the  button  (16).  The  selected  measure-

ment units are shown on the display (14).

– 

Install  the  battery  compartment  lid  (17)  back  to 

its place.

Main unit

– 

Remove the battery compartment lid (8) and insert 

two “AAA” batteries (included), strictly following the 

polarity. 

– 

Install  the  battery  compartment  lid  (8)  back  to 

its place.

UNIT INSTALLATION

– 

Use the flap stand (9) to set the main unit on a flat 

stable  surface,  use  the  stand  (18)  for  the  remote 

sensor (13).

– 

You  can  also  hang  the  main  unit  and  the  sensor 

(13)  on  the  wall  by  using  the  holes  (7)  and  (15), 

respectively.

– 

Place the remote sensor (13) outdoors so that it is 

not  exposed  to  direct  sunlight,  rain  or  snow.    The 

sensor  is  installed  up  to  30  meters  away  from  the 

main unit in the line of sight. The distance from the 

main unit and the sensor to any interference sourc-

es  (such  as  computers,  television  receivers  etc.) 

should be at least 1,5-2 meters.

– 

Do not place the unit near metal frames and do not 

use  appliances  (for  example,  headphones)  oper-

ating  at  the  same  frequency  (433  MHz)  near  the 

weather station.

– 

The  remote  sensor  (13)  operates  within  the  tem-

perature range from –40°С до +60°С. If the outdoor 

temperature is below -20 °C or if the remote sensor 

(13)  can’t  be  installed  outside,  set  it  indoors  and 

install the wired sensor (19) outside.

Note:  Make  sure  that  the  wired  sensor  (19)  is  not 

bent or pinched.

DATE AND TIME SETTING

Note: If the buttons (2) 

 and (5) 

 are not pressed 

within 30 seconds during the setting process, the unit 

will be switched to the current time mode without saving 

the new settings.

2

3

– 

Press  and  hold  the  SET  button  (6)  for  2  seconds, 

the time indication format symbols (12 hour format 

or 24 hour format) will be flashing in the field (12).

– 

Use  the  buttons  (2) 

  and  (5) 

  to  set  the  time 

indication format.

– 

Press  the  SET  button  (6),  the  hour  digits  will  be 

flashing in the field (12).

– 

Use  the  buttons  (2) 

  and  (5) 

  to  set  time  in 

hours. To set the afternoon time in the 12 hour for-

mat, press the buttons (2) 

 and (5) 

 until the 

symbol «PM» appears.

– 

Press  the  SET  button  (6),  the  minute  digits  will 

be flashing.

– 

Use  the  buttons  (2) 

  and  (5) 

  to  set  time  in 

minutes.

– 

Press  the  SET  button  (6),  the  year  digits  will  be 

flashing.

– 

Use the buttons (2) 

 and (5) 

 to set the nec-

essary year.

– 

Press  the  SET  button  (6),  the  month  digits  will  be 

flashing.

– 

Use the buttons (2) 

 and (5) 

 to set the nec-

essary month.

– 

Press  the  SET  button  (6),  the  day  digits  will  be 

flashing. 

– 

Use the buttons (2) 

 and (5) 

 to set the day. 

– 

To save the settings, press the SET button (6).

ALARM SETTING

Note: If the buttons (2) 

 and (5) 

 are not pressed 

within 30 seconds during the setting process, the unit 

will be switched to the current time mode without saving 

the new settings.

– 

To  view  the  alarm  settings,  press  the  ALARM  but-

ton (4).

– 

To  change  the  settings,  press  the  ALARM  button 

(4)  again  and  hold  it  down  for  2  seconds  while  in 

the alarm settings displaying mode. The alarm hour 

digits will be flashing. 

– 

Use the buttons (2) 

 and (5) 

 to set the alarm 

time in hours.

– 

Press the ALARM button (4), the alarm minute dig-

its will be flashing.

– 

Use the buttons (2) 

 and (5) 

 to set the alarm 

time in minutes.

– 

To save the settings, press the ALARM button (4). 

– 

To switch the alarm on/off, enter the alarm settings 

displaying mode by pressing the ALARM button (4). 

While  the  alarm  settings  are  shown  on  the  display, 

press  the  ALARM  button  (4)  again.  If  the  alarm  is 

on, the symbol 

 appears on the display.

Repeating alarm signal 

– 

The alarm signal will sound for 2 minutes if you do 

not press any buttons.

– 

You can switch the alarm signal off for 5 minutes by 

pressing the SNOOZE button (3). The symbol «Zz» 

will  appear  on  the  display,  the  alarm  signal  will  be 

repeated in 5 minutes.

– 

To  switch  the  alarm  sound  signal  off,  press  any 

other button.

DISPLAY BACKLIGHT

To switch the display backlight on, press the SNOOZE-

LIGHT  button  (3).  The  backlight  will  be  on  for  10  se-

conds.

TEMPERATURE AND HUMIDITY MEASUREMENT

The integrated thermometer is used for indoor temper-

ature measurement within the range from 0 °С to +50°С, 

the remote sensor (13) is used for outdoor temperature 

measurement  within  the  range  from  -40°C  to  +60°  C.  

The integrated humidity meter operates within the rela-

tive humidity range from 20% to 90%. If the temperature 

and humidity values are below the specified range, the 

symbols «LL» will be shown in the corresponding field.

– 

The  outdoor  temperature  values  are  displayed  in 

the  field  (10)  «OUTDOOR».  The  indoor  tempera-

ture  and  humidity  data  are  displayed  in  the  field 

(11) «INDOOR»

– 

Temperature  and  relative  humidity  levels  are  mea-

sured every 30 seconds by the unit, and the outdoor 

temperature  is  measured  minutely.  The  data  are 

updated automatically.

Measurement unit selection 

To select the measurement units (Celsius or Fahrenheit 

degrees), press the button (2) 

.

Remote sensor data transmission

When  the  batteries  are  inserted  in  the  remote  sen-

sor  (13),  it  will  start  data  transmission  with  an  about 

1-minute interval. 

– 

If the batteries are inserted in the main unit, the unit 

will start searching the signal from the remote sen-

sor (13). During the search the symbol 

 is shown 

on the display of the main unit.

– 

The  signal  search  takes  about  3  minutes.  Data 

obtained from the remote sensor (13) will be shown 

in the field (10) «OUTDOOR». 

– 

If  there  is  no  remote  sensor  signal,  the  symbols  

«- -. -» will be shown in the field (10) «OUTDOOR».

– 

To start a new search, press and hold down the but-

ton (5) 

 for 2 seconds.

Memory function

The  unit  memory  stores  the  data  on  maximal  and 

minimal  temperature  and  relative  humidity  values 

for the current day. When a new day comes at 0:00, 

the  data  for  the  previous  day  are  deleted  from  the 

unit memory.

– 

Press the MAX/MIN button (1) repeatedly to view:

•  the maximal temperature and humidity values (the 

symbol «MAX» in the corresponding field),

• the minimal values (the symbol «MIN»),

• the current values.

– 

Maximal  or  minimal  temperature  and  humidity  val-

ues are shown on the display within 10 seconds.

– 

To clear the unit memory, press and hold down the 

MAX/MIN button (1) while in the maximal or mini-

mal values displaying mode. 

CLEANING AND CARE

– 

Switch the unit off before cleaning by removing the 

batteries from the battery compartment of the main 

unit and the remote sensor. 

– 

Use a soft cloth to clean the unit. 

– 

Do  not  use  liquid  or  aerosol  detergents  to  clean 

the unit.

STORAGE

– 

Unplug  and  clean  the  unit  before  taking  it  away 

for storage.

– 

Wind  the  wired  temperature  sensor  (19).  Do  not 

wind the sensor wire around the unit.

– 

Keep the unit away from children in a dry cool place.

DELIVERY SET

Weather station main unit – 1 pc.

Remote sensor – 1 pc.

«ААА» batteries – 4 pcs.

Instruction manual  – 1 pc.

TECHNICAL SPECIFICATIONS

Measurements
Main unit

From 0

o

С to +50

o

С

Remote sensor

from -40

o

С to +60

o

С

Temperature measurement 

precision

0,1

o

С

Relative humidity 

measurement

from 20% to 90%

Relative humidity 

measurement precision

1%

Remote sensor data transmission
Transmission frequency

433 MHz

Number of sensors 

connected

1

Transmission range 

Maximum 30 m

Power supply

Main unit

2 «ААА» type batteries 

1,5 V

Remote sensor

2 «ААА» type batteries 

1,5 V

The  manufacturer  preserves  the  right  to  change  the 

specifications  of  the  unit  without  a  preliminary  noti-

fication

Unit operating life is 3 years 

Guarantee 

Details regarding guarantee conditions can be obtained 

from  the  dealer  from  whom  the  appliance  was  pur-

chased.  The  bill  of  sale  or  receipt  must  be  produced 

when making any claim under the terms of this guar-

antee.

This  product  conforms  to  the  EMC-

Requirements  as  laid  down  by  the  Council 

Directive  2004/108/ЕС  and  to  the  Low 

Voltage Regulation (2006/95/ЕС)

 ENGLISH

VT-3531.indd   1

25.06.2014   11:57:05

1
2
Оглавление инструкции
  • Страница 1 из 3
    – Press and hold the SET button (6) for 2 seconds, ENGLISH THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY – • • WIRELESS WEATHER STATION The weather station is intended for temperature and relative humidity level measurement. Use the main unit to measure indoor parameters and the remote sensor for
  • Страница 2 из 3
    русский Внимание! Не разрешайте детям играть с полиэтиленовыми пакетами или упаковочной плёнкой. Опасность удушья! • Не разбирайте прибор самостоятельно, в случае обнаружения неисправности или после падения прибора обратитесь в ближайший авторизованный (уполномоченный) сервисный центр. • Не чистите
  • Страница 3 из 3