CAPACITY OF SCALE: 200G ACCURACY + / - 0.1G

  

CALIBRATION INSTRUCTIONS 

 

THIS SCALE IS ACCURATE WITHIN 0.1g, only calibrate if your readings are inaccurate beyond 0.1g. Allow 
your scale to warm up for several seconds before calibration. Always move your hands very gently 
during calibration as to not cause vibrations or air movement.  

1.

 

Place the scale on a flat stable surface that has NO vibrations and make sure there is absolutely NO air 

movement. (Surface must be extremely stable)  

2. 

Turn the scale off and clear the platform (Make sure nothing is on the platform not even the plastic 

tray)  

3. Turn the scale on by pressing .  

4.When the display shows 0.0, Place a 100 gram weight on the center of the tray.

 

5. Wait 5 seconds for the display to stabilize, then press and hold the 

UNIT

 key until the display flashes 

100.0 twice

. (This will take about 6 seconds)

  

6. Calibration is complete, release the UNIT key and remove the weight from the tray.  

If the readings are inaccurate, perform calibration again..

  

If your scale will not properly calibrate or shows "err" please visit our website for advanced calibration 
& troubleshooting instructions

  

BATTERY INSTRUCTIONS 

 

Use 2 CR2032 3volt batteries. Please make sure the polarity is correct when installing new batteries. 
Slide the locking switch near the battery cover to access batteries. Low batteries are the #1 cause of 
scale malfunction so be sure your batteries are good.  

Advanced Stability Feature (ASF)

  

This scale has a stability indicator (S) in the top left corner of the screen. Whenever the "S" is displayed 
that means the displayed weight is stable.  

Tools (onboard) 

 

The C300 has on-board tools for handling gems and other loose materials. You can find an on-board 
scoop and tweezers on the bottom of the scale (the tweezers are exposed when the scoop is removed)  

CHANGEABLE FACEPLATE COVERS 

 

The C300 comes with four changeable faceplate covers. Use whichever cover you like best. To change 
faceplates please follow the picture-pamphlet included in the box (it’s a very easy process).  

1
2
3
4
Оглавление инструкции
  • Страница 1 из 5
    C300 Convertible Manual This is the Owners Manual and Calibration guide for all C300 Convertible Scales (below). The C300 uses the same internal program as the Palmscale 5.0. So, for advanced programming information, please view the Palmscale 5.0 Advanced Programming/Repair . Low Batteries & bad
  • Страница 2 из 5
    8) If the scale is excessively cold or hot, allow the scale to warm up to normal room temperature for at least 1 hour prior to use. 9) Do not operate a cell phone or cordless phone within 10 feet of the scale**** It may temporarily cause the scale to malfunction 10) If the scale ever reads "Lo" or
  • Страница 3 из 5
    CAPACITY OF SCALE: 200G ACCURACY + / - 0.1G CALIBRATION INSTRUCTIONS THIS SCALE IS ACCURATE WITHIN 0.1g, only calibrate if your readings are inaccurate beyond 0.1g. Allow your scale to warm up for several seconds before calibration. Always move your hands very gently during calibration as to not
  • Страница 4 из 5
    There is an advanced troubleshooting and programming guide available online for this scale at our website. Words of Advice: The C300 is a unique weighing device that is designed to have changeable faceplates to suit your daily mood or personality. Remember that this is a precision instrument. It is
  • Страница 5 из 5