PREPARATION 

1.Installing batteries/Connecting the AC adaptor          

Batteries 

  Battery                                                                                Remove the battery compartment   
  compartment                                                                      cover and insert six batteries(R6P/LR6 

                                                                                            /AAsize) into the battery compartment, 

                                                                                              use extreme care that the polarities   

                                                                                              plus and minus are correct. BE                                                   

                                                                                            CAREFULL Not to push on the tray! 

                                                                                              (Overload / Damage can occur)

 

 
                                                             

  R6P/LR6/AA size 

  Battery compartment cover                              Dry batteries. 
                                                                            (use high powered batteries only) 

 

AC adapter (optional) 

                                                                       

     Plug the AC adapter to the AC 

      AC adaptor                                                           

       

adapter socket on the side. 

      socket                                                                     

       

The AC input requirement could 

                                                                                              be 100,120,220,230 or 240Volts 

                                                                                              (50/60Hz) depending on the area 

                                                                                              where used, so please verify that 

                                                                                              the adaptor is correct 

                                                                               

 

2.Setting up the i101 

!

 

CAUTION 

Avoid placing the scale in direct sunlight, this may cause discoloration or 

malfunction. Place your i101 on a firm weighing table so that the scale is level. 

(The scale will not perform accurately when it is not level.) Make sure there are 

absolutely 

NO

 air currents or vibrations.    They can cause inaccurate readings. 

Place the i101 on a firm surface that is flat and level for accurate weighing. Be 

certain there is no cell or cordless phone interference and no vibrations. 

                                     

                                                           

            3 

WEIGHING 

 

Before weighing 

 

Whenever possible, please allow the scale to warm up for 30 seconds after first 
turning the power on so that the scale will function properly and accurately. 
 

Error messages 

EEEE:    Overload 

:     Low battery 

 

Calibration may be required before weighing. 

Calibration is rarely needed.  Read "CALIBRATION" first and if necessary, 
calibrate your scale for accurate weighing. 
 

Weighing procedures 

 

1.

 

Press [ON/OFF] to turn on the scale. 

 

When the power is turned on, all display segments appear for a few seconds and "0" 

will appear on the display. 

 

2.

 

Select the weighing unit with [UNIT]. 

 

Press 

[UNIT]

 to select a weighing unit "g"

"oz" 

"mg"

"ozt" 

"dwt"

"ct"

"gn" or "pcs". 
Once the unit has been selected, the selected unit will be displayed next to the 
weight value. 
 

3.

 

Start weighing   

 

If you do not use a container for weighing, 

 

Verify the reading is "0". If not, press

 [ZERO] 

to display "0". 

Place objects on the weighing platform to weigh. 
When the reading becomes stable, the stable indicator is displayed. 

 

If you use a container for weighing, 

 

Place an empty container on the platform. 
Wait for the stability indicator to be displayed and press 

[ZERO]

Place the objects to be weighed in the container. 

When the reading becomes stable, the stable indicator is displayed. 

 

1
2
3
4
Оглавление инструкции
  • Страница 1 из 5
    SPECIFICATIONS Model number i101 Platter / Tray Net/gross weight Package Operating Temperature Power source Capacity 100g Division 0.005g φ100mm 510/620g Standard carton: 29×22×14(cm3) 12 Units in one box: 60×45×45(cm3) 0-40c (32-104℉)) 6×AA Size Batteries or AC/AC Adapter 11V/150mA (optional)
  • Страница 2 из 5
    SAFETY PRECAUTIONS All safety messages are identified by the words "WARNING" and "CAUTION". These words mean the following: △WARNING ! △CAUTION ! Important information to alert you to a situation that might cause serious injury and damage to your property if instructions are not followed. Important
  • Страница 3 из 5
    CALIBRATION When to calibrate - calibration is RARELY required. Calibration may be required when the scale is first set up for use, or if the scale is moved to a different altitude or gravitation. This is necessary because the weight of a mass in one location is not necessarily the same in another
  • Страница 4 из 5
    PREPARATION WEIGHING 1.Installing batteries/Connecting the AC adaptor Before weighing Batteries Whenever possible, please allow the scale to warm up for 30 seconds after first turning the power on so that the scale will function properly and accurately. Battery compartment Remove the battery
  • Страница 5 из 5