background image

• Hazardous locations (such as explosive, or corrosive atmos-

pheres).

• Location where the air temperature is very high or there is poor

ventilation.

• Outdoor installations where there is no protection against rain or

freezing temperatures.

DANGER:
Do not use this pump to handle flammable and/or explosive

liquids.

NOTICE:

• Do not use this pump to handle liquids containing abrasive, solid,

or fibrous substances.

• Do not use the pump for flow rates beyond the specified flow

rates on the data plate.

Special applications
Contact the local sales and service representative in the following cas-

es:

• If the density and/or viscosity value of the pumped liquid exceeds

the value of water, such as water with glycol; as it may require a

more powerful motor.

• If the pumped liquid is chemically treated (for example softened,

deionized, demineralized etc.).

• Any situation that is different from the ones that is described and

relate to the nature of the liquid.

3.2  Pump description

See 

Figure 9 

for an explanation of the description code for the pump

and one example.

3.3  Nameplate

The nameplate is a metal label that is located on the bearing bracket.

The name plate lists key product specifications. For more information,

see 

Figure 10 

and 

Figure 11 

.

The nameplate provides information regarding the impeller and casing

material, the mechanical seal and their materials. For more informa-

tion, see 

Figure 12 

.

IMQ or TUV or IRAM or other marks (for electric pump only)
Unless otherwise specified, for products with a mark of electrical-relat-

ed safety approval, the approval refers exclusively to the electrical

pump.

3.4  Design structure

• Dimensions according EN 733 and additional not standardized

extension sizes

• Volute casing pump with back pull out bearing bracket or stub

shaft connection

• Single stage

• For horizontal assembly

Part

Description

Casing

• Radial split volute casing with radial discharge

• Replaceable wear ring

Impeller

• Closed radial impeller with wear rings on both

sides

Shaft seal

• Single mechanical seal acc. EN 12756

• Optional cartridge mechanical seal

Bearings

• Radial ball bearings

• Grease lubrication

• Optional: oil lubrication (Advanced bearing

bracket)

See the sectional drawing 

Figure 13 

.

3.5  Material

The metallic parts of the pump that come in contact with water are

made of the following:

Standard/

Optional

Material

code

Material

casing/

impeller

EN733

range

32–125 to

150-400

Extension

range

125-500,

150-500 to

300-450

Standard

CC

Cast iron /

Cast Iron

X

Standard/

Optional

Material

code

Material

casing/

impeller

EN733

range

32–125 to

150-400

Extension

range

125-500,

150-500 to

300-450

Standard

CB

Cast Iron /

Bronze

X

Standard

CN

Cast Iron /

Stainless

Steel

X

Standard

DC

Ductil Iron /

Cast Iron

X

Standard

DB

Ductil Iron /

Bronze

X

Standard

DN

Ductil Iron /

Stainless

Steel

X

Standard

NN

Stainless

Steel / Stain-

less Steel

X

Optional

RR

Duplex / Du-

plex

X

X

3.6  Mechanical seal

Unbalanced single mechanical seal acc. EN 12756, version K Dimen-

sions. See 

Table 14 

.

3.7  Application limits

Maximum working pressure
This flow chart shows the maximum working pressure depending on

the pump model and the temperature of the pumped liquid.

P

1max

 + P

max

≤ PN

P

1max

Maximum inlet pressure

P

max

Maximum pressure generated by the pump

PN

Maximum operating pressure

Liquid temperature intervals

Version

Gasket

Minimum

Maximum

Standard

EPDM

-20°C (-4°F)

140°C (284°F)

Optional

FPM (FKM)

-10°C (14°F)

90°C (194°F)

For special requirements, contact the Sales and Service Department.

Maximum number of starts per hour
This table shows the number of starts allowed per hour for motors sup-

plied by Lowara:

kW

0.25 -

3.00

4.00 -

7.50

11 - 22 30 - 37 45 - 75

90 –

160

185 -

355

Starts

per

hour

60

40

25

16

8

4

3

en - Translation of the original instructions

14

e-NSC Installation, Operation, and Maintenance Manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
Оглавление инструкции

Document Outline