![background image](/i/hotpoint-ariston/155787/hotpoint-ariston-fh-g/h/hotpoint-ariston-fh-g-024.png)
24
GB
Burner and Nozzle specifications
*
At 15°C and 1013,25 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
3
Table 1
Liquid gas
Natural gas
Burner
Thermal Power
kW (gross heat value)*
By-pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm)
***
**
(mm)
Oven
2,60
1,00
49
78
189
186
119
248
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Electric Part
Category
Thermal Power
kW (1)
Voltage frequency
Power
(W)
II2H3+
2,60 (189 g/h - G30)
(186 g/h - G31)
220-240V ~50-60Hz
2250
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).
Gas Part