background image

Memory Protection

Advanced ECC

Memory Online Spare Mode (Rank Spare Mode)

Memory

One of the following
depending on Model

Type

HP SmartMemory

DDR4 Load Reduced (LRDIMM), or Registered (RDIMM)

Standard (Pre-
configured Models)

128GB (4 x 32GB) DDR4 2133MHz RDIMMs at 1.2V
64GB (4 x 16GB) DDR4 2133MHz RDIMMs at 1.2V
32GB (2 x 16GB) DDR4 2133MHz RDIMMs at 1.2V
32GB (2 x 16GB) DDR4 2133MHz RDIMMs at 1.2V
16GB (2 x 8GB) DDR4 2133MHz RDIMMs at 1.2V
16GB (2 x 8GB) DDR4 2133MHz RDIMMs at 1.2V

Maximum (LRDIMM)

512GB (16 x 32GB) up to 2133MHz at 1.2V

Maximum (RDIMM)

256GB (16 x 16GB) up to 2133MHz at 1.2V

NOTE: 

HP memory from previous generation servers (DDR3) is not compatible with this server.

HP SmartMemory is required to realize the memory performance improvements and enhanced
functionality listed in this document for Gen9. For additional information, please see the HP
SmartMemory QuickSpecs at:

http://www8.hp.com/h20195/v2/GetHTML.aspx?docname=c04111535

NOTE: 

LRDIMM and RDIMM are distinct memory technologies and cannot be mixed within a

server.

NOTE: 

Depending on the memory configuration and processor model, the memory speed may

run at 2133MHz, 1866MHz, or 1600MHz. Please see Memory Population Table or the Online
Memory Configuration Tool at: 

http://h22195.www2.hp.com/MemoryTool/Home/Legal

Network Controller

One of the following
depending on Model

One (1) 20Gb 2-port FlexFabric FLB, 10Gb 2-port HP FlexFabric FLB, or 10Gb 2-port Ethernet
FLB

NOTE: 

Supports FCoE, , TCP/IP offload engine, hardware-based accelerated iSCSI, iSCSI boot,

and autosensing 10Gb/1Gb Ethernet.

NOTE: 

Each port is autosensing the speed, and can interoperate with 1Gb HP BladeSystem c-

Class interconnect components. Both ports will operate at the same speed.

NOTE: 

FlexFabric capabilities require the use of an HP Virtual Connect FlexFabric module.

Fibre Channel over Ethernet (FCoE) is supported with HP interconnects. Learn more at:

http://www.hp.com/go/bladesystem/interconnects

One (1) HP FlexFabric 10Gb 2-port 536FLB FlexibleLOM
One (1) HP FlexFabric 20Gb 2-port 650FLB FlexibleLOM

NOTE: 

FlexibleLOMs are not compatible with prior generation c-Class server blades

Standard iLO Network Controller:
One (1) 10/100 Mbps port for the HP iLO 4 to Onboard Administrator link. The Onboard
Administrator (with 10/100/1000 Mbps) to BladeSystem link is 1Gbps

QuickSpecs

HP ProLiant BL460c Generation 9 (Gen9) Server

Blade

Standard Features

DA - 15052   Worldwide QuickSpecs — Version 1 — 9.9.2014

Page  4

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41