Инструкция для TEC APO160FL

(скачивание инструкции бесплатно)
Формат файла: PDF
Доступность: Бесплатно как и все руководства на сайте. Без регистрации и SMS.
Дополнительно: Чтение инструкции онлайн
background image

4.  The Feather Touch 3545 focuser is assembled to the OTA via the Focuser Mounting Flange (fig. 6.1), and
the Focuser Locking Collar (fig. 6.2). Loosening the focuser Locking Collar allows the focuser to be rotated to
any position relative to the telescope for ease of use. Once the focuser has been positioned, it can be locked by
turning the Locking Collar by either grabbing the grooves on this collar or by grabbing the optional Locking
Stems and rotating the Locking Collar clockwise until it is tight. The Locking Stems (6.3) help to provide a
better grip for tightening the collar. They can however be replaced with the 10-32 Button Head Cap Screws
for a cleaner look if that is desired. 

NOTE:

The focuser can be removed by loosening the Locking Collar and unscrewing it completely and then

pulling the focuser from the Adapter Flange. This should only be done in rare circumstances and after contact-
ing Starlight Instruments or TEC because of possible damage that may result. 

5.  The drag between the Focuser Housing (fig. 6.6) and the Draw Tube (fig. 6.9) can be adjusted by using
two adjustment methods. The Tension Adjustment Screw can be adjusted using a 3/16 inch Allen wrench.
Only a slight amount of rotation on this screw makes a notable difference. Tightening this screw will allow
larger loads to be lifted without the focuser moving from the dead weight that may be attached to it and it will
also decrease the amount of deflection during positional changes during long exposures. Generally the factory
settings should be sufficient for most applications. 
In addition, adjustment can be done in a simpler way - by tightening a thumb screw (not shown in the picture,
but easy to find) under the pinion assembly).

6.  In the event that different equipment such as: an optional Field Flattener or AP 2.7" threaded End Cap
(available from Starlight Instruments) is needed at the end of the focuser, the Draw Tube End Cap (fig. 6.10)
can be removed by loosening the (3) 6-32 socket head set screw (6.11) and then unscrewing the back.

7.  The 2 inch Eyepiece Holder does not use traditional thumb screws. This focuser uses an Eyepiece Collet
Locking Nut (fig. 6.12) and an Eyepiece Collet Sleeve (6.13). This design assures that the eyepiece or imaging
equipment is always precisely positioned and held into place during imaging. To secure your eyepiece, insert
the eyepiece into the 2 inch opening making sure that the nut has been turned counter clock wise to open the
collet sleeve and push in the eyepiece. Tighten the Collet Nut clockwise until it is tight.

WARNING: Failure to tighten the Collet Nut can result in personal injury and/or damage to equip-
ment. Always make sure that the eyepiece is secured properly during use. 

WARNING: Never point the scope to the sun without proper filtering or without the Front Cover in
place. Failure to do so can result in personal injury or damage to the collet locking sleeve and/or optics.
The Collet Sleeve is plastic and can melt if it gets too hot. Possible fumes during melting can cause fog-
ging or damage to the optics.

8.  If a finder base is to be attached to the focuser housing make sure that the screws being used are the proper
length. 

WARNING: If they are too long they will contact the draw tube thereby causing damage to the
anodized surface of the draw tube.

WARRANTY

Starlight Instruments Incorporated guarantees this product to be free of any defects in material or workman-
ship for 3 years to the original owner. Disassembly of focuser outside of the described items voids all war-
ranties. 
Starlight Instruments Inc. • P.O. Box 68282, Schaumburg, IL 60168-0282. USA. 
Phone: 

847-985-9595

.

4

1
2
3
4
5
6
7
8
9
10
Оглавление инструкции
  • Страница 1 из 11
    OWNER’S MANUAL 2006
  • Страница 2 из 11
    IMPORTANT - PLEASE READ THIS MANUAL BEFORE USING YOUR TELESCOPE SAFETY WARNINGS Do not look at the sun through the telescope! Viewing the sun through the telescope without special equipment (Solar Filters) will cause permanent visual impairment and telescope parts damage. Do not disassemble!
  • Страница 3 из 11
    OVERVIEW This manual has been written to help you enjoy using your TEC APO 160 refractor. The APO 160 has number of features that in a given combination are rarely found in one scope: Precision apochromatic objective with modern coating that makes lenses almost invisible. Retractable Dew Shield.
  • Страница 4 из 11
    FEATHER TOUCH FOCUSER MODEL 3545 Care and use of the Feather Touch 3545 The Feather Touch 3545 was a collaborative design effort between Telescope Engineering and Starlight Instruments for TEC’s line of fine refractors. It was designed to provide the user the with the best possible control while
  • Страница 5 из 11
    4. The Feather Touch 3545 focuser is assembled to the OTA via the Focuser Mounting Flange (fig. 6.1), and the Focuser Locking Collar (fig. 6.2). Loosening the focuser Locking Collar allows the focuser to be rotated to any position relative to the telescope for ease of use. Once the focuser has been
  • Страница 6 из 11
    5
  • Страница 7 из 11
    ACCESSORIES 1 TEC is offering a line of accessories made in shop: tube rings, plates, finder bracket; other brands of accessories could be used with our telescopes as well. 2 3 4 5 TUBE RINGS CNC machined, black anodized aluminum, compact and lightweight design with stainless steel latches (set of
  • Страница 8 из 11
    TEC FINDERSCOPE BRACKET 8 7 6 5 The TEC Finderscope Bracket is designed to hold a traditional 50mm optical finder or a Red Dot sight. This new design requires only 2 thumb 9 screws for alignment. It looks and works in a much more elegant way. The Finderscope Bracket contains the following parts:
  • Страница 9 из 11
    EYEPIECE TURRET Eyepiece Turret with Mahogany case. Precision holder for five 1.25" eyepieces. Diagonal mirror made of Sitall or Quartz. Case safely holds six 1.25" eyepieces and I-Turret. Case dimensions: 5.5" x 8.25" x 10.75"; weight - 2lb. This new component will let you change your favourite
  • Страница 10 из 11
    FOCUSING DIAGRAM The focuser end of every model of TEC telescopes is the same and shown below: Focusing tube is completely "IN" Unvignetted field dia. ~1.0" 7,0" BACK FOCUS Focusing tube is completely "OUT" Unvignetted field dia. ~1.6" 3" long extension tube is required for straight through viewing
  • Страница 11 из 11