Accurate Specifications
Accuracy: (a% reading + b digits), guarantee for 1 year.
Operating temperature: 23ºC 5ºC
Relative humidity: 85%R.H
Temperature coefficient: 0.1x(specified accuracy)/1ºC
A. DC Voltage
Range
Resolution
Accuracy
Overload protection
400.0mV
4.000V
40.00V
400.0V
600V
0.1mV
1mV
10mV
100mV
1V
(0.8%+3)
(0.8%+1)
(1%+3)
600V DC/AC
Remarks:
Input impedance: 10M
Model UT203/204: OPERATING MANUAL