background image

19

ULTRACURVE PRO DEQ2496 User Manual

Digital Input 2

Type 

TOSLINK optical

Standard 

AES/EBU or S/PDIF

Digital Output 1

Type 

XLR transformer-balanced

Standard 

AES/EBU or S/PDIF

Impedance 

110 Ω

Output level 

3.5 V peak-to-peak

Digital Output 2

Type 

TOSLINK optical

Standard 

AES/EBU or S/PDIF

Sync Input

Type BNC
Standard 

Wordclock (1 x sample rate)

Input impedance 

50 kΩ

Nom. level 

2 - 6 V peak-to-peak

MIDI Interface

Type 

5-pole DIN jacks In/Out/Thru

Implementation 

cf. MIDI implementation chart

Digital Processing

Converter 

24-bit Delta-Sigma,  

64/128-oversampling (AKM®)

Sample rate 

44.1, 48, 88.2, 96 kHz

Graphic Equalizer (GEQ)

Type 

digital 1/3-oct EQ

Frequency range 

20 Hz to 20 kHz, 31 1/3-oct. bands 

according to ISO frequencies

Bandwidth 1/3-oct.
Control range 

+15 to -15 dB

Parametric Equalizer (PEQ)

Type 

max. 10 independent, fully parametric 

filters per channel

Frequency range 

20 Hz to 20 kHz

Bandwidth 

1/10 to 10 oct., shelving filters (6 and 12 

dB)

Control range 

+15 to -15 dB

Dynamic Equalizer (DEQ)

Type 

max. 3 independent, fully parametric 

filters per channel

Frequency range 

20 Hz to 20 kHz

Bandwidth 

1/10 to 10 oct., shelving filters (6 and 12 

dB)

Control range 

+15 to -15 dB

Threshold 

variable from 0 to -60 dB

Attack 

0 to 200 msec

Release 

20 to 4,000 msec

Ratio 

1:2 to 1:100

Feedback Destroyer (FBD)

Type 

digital signal analysis for 

feedback identification

Filter 

max. 10 digital notch filters per 

channel, programmable or as automatic 

feedback suppression system

Frequency range 

20 Hz to 20 kHz

Bandwidth 

1/10 to 1/60 oct.

Control range 

0 to -60 dB

Digital Delay

Type 

digital stereo delay

Max. delay time 

300 ms, independently adjustable for 

each channel

Min. resolution 

0.02 ms

Delay units 

seconds, meters or feet

Level Meter

Type 

digital level meter with simultaneous 

graphic display of peak and RMS values 

and virtual analog VU meter

SPL Meter

Weighting 

dB (A), dB (C) or OFF

Microphone calibration 

-42 dBV/Pa to -6 dBV/Pa

Dynamics

Type 

Expander or compressor with digital IGC 

(Interactive Gain Control)

Threshold 

variable from 0 to -60 dB

Attack 

0 to 200 msec

Release 

20 to 4,000 msec

Ratio 

1:1.1 to 1:100