2.3.4  Signal assignment

Fig. 2.12: Assignment switches of the main section

USB/2-TR TO MAIN MIX

When the 

USB/2-TR TO MAIN

 switch is depressed, the USB/2-Track input is 

assigned to the main mix, providing an additional input for tape machines, 

computers, MIDI instruments or other signal sources that do not require any 

processing. The 2-Track Out/USB recording signal are muted to avoid feedback.

USB/2-TR TO PHONES/CTRL RM 

(Q502: USB/2-TR TO PHONES)

Press the 

USB/2-TR TO PHONES/CTRL RM

 switch if you want to monitor 

the 2-Track or USB input via the CTRL ROOM OUT. This provides an easy 

way to monitor signals coming back from tape to ensure that they are 

recording correctly.

FX TO CTRL ROOM

If you want to monitor only the FX send signal in your headphones or monitor 

speaker(s), press the FX TO CTRL switch. This mutes the main mix signal while 

routing the FX SEND output to the monitor(s). The XENYX Q802USB and Q502USB 

do not feature this switch.

2.3.5  Phantom power and LED displays

Fig. 2.13: Phantom power and control LEDs

+48 V

The red 

+48 V

 LED lights up when phantom power is on. The 

PHANTOM

 switch 

activates the phantom power supply on the XLR connectors of all mono channels. 

◊ 

Please do not connect microphones to the mixer (or the stagebox/
wallbox) as long as the phantom power supply is switched on. 
Connect the microphones before you switch on the power supply. 
In addition, the monitor/PA loudspeakers should be muted before you 
activate the phantom power supply. After switching on, wait approx. 
one minute in order to allow system stabilization.

POWER

The 

POWER

 LED indicates that the console is powered on.

Level indicator

The high-precision 4-segment display accurately displays the relevant 

signal level.

LEVEL SETTING

: To correctly set the gains of the channels, first set the LEVEL 

controls of the input channels to their center positions (0 dB). Then use the GAIN 

controls to increase the input amplification until signal peaks show 0 dB on the 

level meter.
When recording to digital recorders, the recorder’s peak meter should not go into 

overload. While analog recorders can be overloaded to some extent, creating 

only a certain amount of distortion (which is common and often desirable), 

digital recorders distort quickly when overloaded. In addition, digital distortion is 

not only undesirable, but also renders your recording completely useless.

◊ 

The peak meters of your XENYX display the level virtually independent 
of frequency. A recording level of 0 dB is recommended for all 
signal types.

2.4  USB Connector

Fig 2.14: USB connector"]

USB CONNECTOR

Connect your mixer to a computer using a standard USB cable. This enables a 

stereo signal to be sent to and from your mixer and computer. The signal sent 

from the mixer to the computer is the same as the main bus. The audio returning 

from the computer into the mixer appears directly in the main and/or control 

room bus (depending on USB/2TR to MAIN and PHONES/CTRL RM buttons).
NOTE: The mixer cannot be bus-powered via USB! Always use the included power 

adaptor to supply power to the mixer.

3.  Installation

3.1  Mains connection

AC POWER IN

Connect the power supply to the 3-pin mains connector on the rear of the 

console. Use the AC adapter supplied to connect the console to the mains. 

The adapter complies with all applicable safety standards.

◊ 

Please use only the power supply unit provided with the console.

◊ 

Never connect the XENYX to the power supply unit while the latter is 
connected to the mains! First connect the console to the power supply 
unit, then connect the power supply unit to the mains.

◊ 

Please note that both the power supply unit and the mixing console 
heat up considerably during operation. This is completely normal.