4. Remove the Electrostatic Filter from its support frame

as shown in the Figure on the left (Not applicable to

the units without electrostatic filter).

Do not touch this Electrostatic Filter within 10

minutes after opening the inlet grille, it may

cause an electric shock.

Clean the Electrostatic Filter with mild detergent or

water and dry in the sunlight for two hours.

Before re-install the Electrostatic Filter, check whether

the corona line or support frame is damaged or not.

5. Install the air freshening filter back into position.

6. Insert the upper portion of air filter back into the unit

taking care that the left and right edges line up

correctly and place filter into position.

9

Electrostatic
Filter

Maintenance

Checks before operation

If you plan to idle the unit for a long time, perform the
following:
(1) Operate the fan for about half a day to dry the

inside of the unit.

(2) Stop the air conditioner and disconnect power.

(3) The outdoor unit requires periodic maintenance

and cleaning. Do not attempt to do this yourself.
Contact your dealer or servicer.

Remove the batteries from the remote controller.

Check that the wiring is not broken off or disconnected.

Check that the air filter is installed.

Check if the air outlet or inlet is blocked after the
air conditioner has not been used for a long time.

CAUTIONS

Do not touch the metal parts of the unit when
removing the filter. Injuries can occur when
handling sharp metal edges.
Do not use water to clean inside the air conditioner.
Exposure to water can destroy the insulation,
leading to possible electric shock.
When cleaning the unit, first make sure that the
power and circuit breaker are turned off.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Оглавление инструкции
  • Страница 1 из 16
    USE'S MANUAL SPLIT-TYPE ROOM AIR CONDITIONER MODEL #: DSB-075LH DSB-095LH DSB-125LH DSB-185LH Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner. S1
  • Страница 2 из 16
    CONTENTS SAFETY PRECAUTIONS ....................................................................................... 1 PARTS NAMES ..................................................................................................... 4 MANUAL OPERATION
  • Страница 3 из 16
    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. ! WARNING This symbol
  • Страница 4 из 16
    ! CAUTION Do not clean the air conditioner with water. When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. ! ! Do not put a pet or house plant where it will be exposed to direct air flow. Do not clean unit when power is on as it may cause fire and
  • Страница 5 из 16
    Prior to Operation 1. Contact an installation specialist for installation. 2. Make sure the unit is grounded efficiently. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5. Do not use an extension cord. 6. Do not start/stop operation by
  • Страница 6 из 16
    PARTS NAMES Indoor unit Indoor unit 2 1 7 4 3 8 10 6 5 SET AUT COO O DRY L HEA T TEM 9 PER ATU 11 RE ( C) FAN HIG MED H LOW TEM P MOD 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6. Vertical air flow louver 7. Display panel 8. Remote controller signal
  • Страница 7 из 16
    MANUAL OPERATION Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted. Open and lift the front panel up to an angle until it remains fixed with a clicking sound. 2 One press of the manual control button will lead to the forced AUTO
  • Страница 8 из 16
    ADJUSTING AIR FLOW DIRECTION Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. Adjusting the Vertical Air Flow Direction (up - down) The air
  • Страница 9 из 16
    ! CAUTION The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set). Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode. Otherwise, condensation may occur on
  • Страница 10 из 16
    MAINTENANCE WARNING Household Drain Cleaner No It is necessary to stop the air conditioner and disconnect the power supply before cleaning. Cleaning the indoor unit and remote controller CAUTIONS Thinner Use a dry cloth to wipe the indoor unit and remote controller. A cloth dampened with cold water
  • Страница 11 из 16
    4. Remove the Electrostatic Filter from its support frame as shown in the Figure on the left (Not applicable to the units without electrostatic filter). Do not touch this Electrostatic Filter within 10 Electrostatic Filter minutes after opening the inlet grille, it may cause an electric shock.
  • Страница 12 из 16
    OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when
  • Страница 13 из 16
    7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8. Heating mode (For cooling and heating models only) The air
  • Страница 14 из 16
    Troubleshooting tips Malfunctions and Solutions Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly(5 times every second) and this flash cannot be fixed