background image

Prior to Operation

Usage

Cleaning and maintenance

Service

Service

1. Contact an installation specialist for installation.
2. Make sure the unit is grounded efficiently.
3. Do not use a damaged or non-standard power cord.
4. Do not share the same outlet with other appliances.
5. Do not use an extension cord.
6. Do not start/stop operation by shutting off the power supply.

1. Exposure to direct airflow for an extended period of time could be hazardous

to your health. Do not expose occupants, pets, or plants to direct airflow for
extended periods of time.

2. Due to the possibility of oxygen deficiency, ventilate the room when used

together with stoves or other heating devices.

3. Do not use this air conditioner for non-specified special purposes (e.g.

Preserving precision devices, food, pets, plants, and art objects). Usage in
such a manner could harm such property.

1. Do not touch the metal parts of the unit when removing the filter. Injuries

can occur when handling sharp metal edges.

2. Do not use water to clean inside the air conditioner. Exposure to water can

destroy the insulation, leading to possible electric shock.

3. When cleaning the unit, first make sure that the power and circuit breaker

are turned off.

For repair and maintenance, contact your authorised service dealer.

3

Operating temperature

Mode

Cooling operation

Heating operation

Drying operation

Temperature

1. If air conditioner is used outside of the above conditions, certain safety protection

features may come into operation and cause the unit to function abnormally.

2. Room relative humidity less than 80%. If the air conditioner operates in excess of this

figure, the surface of the air conditioner may attract condensation. Please sets the vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

3. Optimum performance will be achieved within these operating temperature.

Room temperature

Outdoor temperature

17 C

32 C

18 C

43 C

17 C

30 C

-7 C

24 C

17 C

32 C

18 C

43 C

~

CAUTION:

~

~

~

~

~

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Оглавление инструкции
  • Страница 1 из 16
    USE'S MANUAL SPLIT-TYPE ROOM AIR CONDITIONER MODEL #: DSB-075LH DSB-095LH DSB-125LH DSB-185LH Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner. S1
  • Страница 2 из 16
    CONTENTS SAFETY PRECAUTIONS ....................................................................................... 1 PARTS NAMES ..................................................................................................... 4 MANUAL OPERATION
  • Страница 3 из 16
    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. ! WARNING This symbol
  • Страница 4 из 16
    ! CAUTION Do not clean the air conditioner with water. When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. ! ! Do not put a pet or house plant where it will be exposed to direct air flow. Do not clean unit when power is on as it may cause fire and
  • Страница 5 из 16
    Prior to Operation 1. Contact an installation specialist for installation. 2. Make sure the unit is grounded efficiently. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5. Do not use an extension cord. 6. Do not start/stop operation by
  • Страница 6 из 16
    PARTS NAMES Indoor unit Indoor unit 2 1 7 4 3 8 10 6 5 SET AUT COO O DRY L HEA T TEM 9 PER ATU 11 RE ( C) FAN HIG MED H LOW TEM P MOD 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6. Vertical air flow louver 7. Display panel 8. Remote controller signal
  • Страница 7 из 16
    MANUAL OPERATION Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted. Open and lift the front panel up to an angle until it remains fixed with a clicking sound. 2 One press of the manual control button will lead to the forced AUTO
  • Страница 8 из 16
    ADJUSTING AIR FLOW DIRECTION Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. Adjusting the Vertical Air Flow Direction (up - down) The air
  • Страница 9 из 16
    ! CAUTION The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set). Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode. Otherwise, condensation may occur on
  • Страница 10 из 16
    MAINTENANCE WARNING Household Drain Cleaner No It is necessary to stop the air conditioner and disconnect the power supply before cleaning. Cleaning the indoor unit and remote controller CAUTIONS Thinner Use a dry cloth to wipe the indoor unit and remote controller. A cloth dampened with cold water
  • Страница 11 из 16
    4. Remove the Electrostatic Filter from its support frame as shown in the Figure on the left (Not applicable to the units without electrostatic filter). Do not touch this Electrostatic Filter within 10 Electrostatic Filter minutes after opening the inlet grille, it may cause an electric shock.
  • Страница 12 из 16
    OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when
  • Страница 13 из 16
    7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8. Heating mode (For cooling and heating models only) The air
  • Страница 14 из 16
    Troubleshooting tips Malfunctions and Solutions Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly(5 times every second) and this flash cannot be fixed
  • Страница 15 из 16
    ABOUT THIS MANUAL
  • Страница 16 из 16