6.

 

The scale has an 

Auto-Off feature

 that turns off the scale after lapses of non-activity. If the scale 

is in a room with wind or air movement, it may sense the pressure of the air and not auto-off. In 
this case you must use the manual shutoff. Simply press the main big button to turn the scale off 
manually.  

7.

 

Gram / Ounce Function:

 This scale has the ability to weigh in either gram or ounce mode. 

Pressing the G/OZ key does the selection of grams or ounces. Turn the scale on Ð the scale will 
start in Gram mode. Press the G/OZ key. The scale is now in Ounce mode.  

BATTERY INSTRUCTIONS

 

Use 4 AAA 6volt heavy duty or alkaline batteries. Please make sure the polarity is correct when installing 
new batteries. You should refer to the diagram on the battery compartment.  

1SCALE 200 VERSION 3.0 ADVANCED PROGRAMMING

 

These instructions are to be used only if the scale locks up showing "ERR" or needs to be hard reset. This 
is not an easy procedure and must only be done when absolutely necessary.  

These instructions are only for the 1scale 200 version 3.0. The 3.0 has 3 buttons on the front of the 
scale. If you only have 1 button on the front of your scale you have version 1.0 or 2.0.  

Please read the entire manual before you attempt advanced programming.  

   

1.

 

Make sure the yellow spacer is removed, the glass platform is installed, and nothing is on the 
platform.  

2.

 

Place the scale on a flat stable surface that has NO vibrations and make sure there is absolutely 
NO air movement.  

3.

 

Be sure there are no causes of electronic interference within 15 feet of the scale such as Cell or 
cordless phones, etc..  

4.

 

Make sure nothing is on the glass platform and the scale should be off with the yellow spacer 
removed.  

5.

 

Use a pen or paperclip to press and hold the recessed hidden RESET switch next to the TARE key. 
(it is the hidden recessed button next to the TARE key, you will need a bent paperclip to press 
it).  

6.

 

While keeping the RESET switch depressed, press and release the big main button to turn the 
scale on. 

Do not release the Reset Button.

  

7.

 

After a few seconds, the display will show "0.0g", now you can release the reset switch.  

8.

 

Press and hold the BIG MAIN BUTTON for 15 seconds. The display will then show a random 4 
digit figure.  

1
2
3
4
5
6
7
Оглавление инструкции
  • Страница 1 из 8
    1scale Owner's Manual Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns from consumers. Fully 60% of consumer returns are battery related problems. This sounds silly but it's true! A scale will perform
  • Страница 2 из 8
    Note : If the battery symbol appears in the display during normal operation, it means low battery power. It is time to replace the battery. If the power is too low, it will show “Lo” when power on and then turn off automatically. Weighing Function 1. Turn the scale on by pressing the key below the
  • Страница 3 из 8
    3. Do not subject the unit to excessive force, shock, dust, temperature, direct sunlight, heavy rain or humidity, which may result in malfunction, shorter electronic life span, battery damage or distorted parts. 4. Do not tamper with the unit’s internal components. It will invalidate the warranty
  • Страница 4 из 8
     To clean the scale, wipe the surface with a clean damp cloth or mild non-abrasive cleaner. Do not use an abrasive cleaner it will damage the finish.  Do not overload the scale. That is, do not place anything that weighs more then 200 Grams on the scale. It may permanently damage the load cell. 
  • Страница 5 из 8
    6. The scale has an Auto-Off feature that turns off the scale after lapses of non-activity. If the scale is in a room with wind or air movement, it may sense the pressure of the air and not auto-off. In this case you must use the manual shutoff. Simply press the main big button to turn the scale
  • Страница 6 из 8
    9. Gently Place a 200g standard weight on the platform. The displayed figure will increase. 10. Wait 10 seconds for the display to stabilize and then gently press the Big Main Button once. The display should change to 0000. 11. Adjust the settings by using the Tare key (shifts the blinking digit)
  • Страница 7 из 8
    21. Turn the scale back on and test some weight readings.If the readings are still inaccurate, perform hard reset again from step 1 and try again. If after several attempts the scale still shows "err" or will not perform properly, please return it to us for repair. SPECIAL ADVANCED PROGRAMMING
  • Страница 8 из 8