 15 

-

Unit indication section

Models  All models

4.2 Back-up switch

When the remote controller batteries become weak, or if the remote controller is lost or malfunctioning, this switch may be used to turn

the unit on and off.

(a)

Operation

Push the switch once to place the unit in the automatic mode. Push it once more to turn the unit off.

(b)

Details of operation

The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by sensor),

whether to go into the cooling, thermal dry or heating modes.

Function

Room temperature

Operation mode

setting

Fan speed

Flap

Timer switch

Cooling

About 25ºC

Thermal dry

About 25ºC

Auto

Auto

Continuous

Heating

About 26ºC

4.3 Power blackout auto restart function

(1)

Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it

being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.

(2)

The following settings will be cancelled:

(a)

Timer settings

(b)

High-power operations

Notes (1) The power blackout auto restart function is set at on when the air-conditioner is shipped from the factory.

Consult with your dealer if this function needs to be switched off.

(2) When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.

(3) If the jumper wire (J7) “REMOTE/AUTORESTART” is cut, auto restart is disabled. (See the diagram at right)

ON/OFF button

ECONOMY light (orange)

Illuminates during ECONOMY operation.

TIMER light (yellow)

Illuminates during TIMER operation.

HI POWER light (green)

Illuminates during HI POWER operation.

RUN (HOT KEEP) light (green)

Illuminates during operation.

Flashes at air flow stop due to the ‘HOT KEEP’.

     (Heat pump type only)

Опубликовано TopClimat

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41