![background image](/i/zyxel/148476/zyxel-xs3900-48f/h/zyxel-xs3900-48f-060.png)
Chapter 4 The Web Configurator
XS3900-48F User’s Guide
60
bit and flow control set to none. The password will also be reset to “1234” and the IP address to
192.168.1.1.
To upload the configuration file, do the following:
1
Connect to the console port using a computer with terminal emulation software. See
for details.
2
Disconnect and reconnect the Switch’s power to begin a session. When you reconnect the Switch’s
power, you will see the initial screen.
3
When you see the message “
Press any key to enter Debug Mode within 3 seconds ...
” press
any key to enter debug mode.
4
Type
atlc
after the “
Enter Debug Mode
” message.
5
Wait for the “
Starting XMODEM upload
” message before activating XMODEM upload on your
terminal.
6
After a configuration file upload, type
atgo
to restart the Switch.
Figure 18
Resetting the Switch: Via the Console Port
The Switch is now reinitialized with a default configuration file including the default password of
“1234”.
Bootbase Version: V1.00 | 01/13/2011 19:34:13
RAM: Size = 524288 Kbytes
ZyNOS Version: V4.00(BVG.0)b6 | 01/28/2011 14:44:24
Press any key to enter debug mode within 3 seconds.
.....................................
Enter Debug Mode
ras> atlc
Starting XMODEM upload (CRC mode)....
CCCCCCCCCCCCCCCC
Total 393216 bytes received.
Erasing..
................................................................
OK
ras> atgo