C. Rebuilding an Array

Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding applies 

only to fault-tolerant arrays such as RAID 1, RAID 5 or RAID 10 arrays. The procedures below assume a new 

drive is added to replace a failed drive to rebuild a RAID 1 array. (Note: The new drive must have equal or 

greater capacity than the old one.)
Turn off your computer and replace the failed hard drive with a new one. Restart your computer.
•  Enabling Automatic Rebuild

Step 1:

When the message "Press <Ctrl-I> to enter Configuration Utility" appears, press <Ctrl> + <I> to enter the

RAID Configuration Utility. The following screen appears after you enter the RAID Configuration Utility.

Step 2:

Select the new hard drive to add into the array to be rebuilt and press <Enter>. The following screen appears, 

indicating that an automatic rebuild will be performed after you enter the operating system (look for the Intel 

Rapid Storage Technology icon   in the notification area, which will show that a RAID volume is being

rebuilt). If you do not enable automatic rebuild on this stage, you have to manually rebuild the array in the 

operating system (see the next page for more details).

Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1046

Copyright(C) 2003-10 Intel Corporation.  All Rights Reserved.

3.  Reset Disks to Non-RAID

4.  Exit

RAID Volumes :

None defined.

Physical Disks :

Port 

Drive Model 

 

Serial # 

 

Size 

Type/Status(Vol ID)

0   

ST3120026AS   

3JT354CP 

 

111.7GB

 

Member Disk (0)

1   

WDC WD800JD-22LS 

WD-WMAM9W736333 

111.7GB

 

Non-RAID Disk

   

[hi]-Select  

[ESC]-Exit 

[ENTER]-Select Menu

[ DISK/VOLUME INFORMATION ]

[ MAIN MENU ]

1.  Create RAID Volume

2.  Delete RAID Volume

DEGRADED VOLUME DETECTED

 ]

  [hi]-Previous/Next 

[ENTER]-Select 

[ESC]-Exit

"Degraded volume and disk available for rebuilding detected. Selecting 

a disk initiates a rebuild. Rebuild completes in the operating system.

Select the port of the destination disk for rebuilding (ESC to exit):

  Port Drive Model  

 

Serial #      

 

Size

  1 

WDC WD800JD-22LS 

 

WD-WMAM9W736333 

111.7GB

Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1046

Copyright(C) 2003-10 Intel Corporation.  All Rights Reserved.

RAID Volumes :

ID  

Name  

 

Level 

 

Strip 

Size 

Status 

Bootable

0   

Volume0   

RAID1(Mirror) 

N/A 

111.7GB 

Rebuild

 

Yes

Physical Devices :

Port 

Devices Model   

Serial # 

 

Size 

Type/Status(Vol ID)

0   

ST3120026AS   

3JT354CP 

 

111.7GB

 

Member Disk (0)

1   

WDC WD800JD-22LS 

WD-WMAM9W736333 

111.7GB

 

Member Disk (0)

   

[hi]-Select  

[ESC]-Exit 

[ENTER]-Select Menu

[ DISK/VOLUME INFORMATION ]

Volumes with "Rebuild" status will be rebuilt within the operating system.

3.  Reset Disks to Non-RAID

4.  Recovery Volume Options

[ MAIN MENU ]

1.  Create RAID Volume

2.  Delete RAID Volume

5.  Exit

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
Оглавление инструкции

Document Outline