![background image](/i/zyxel/144208/zyxel-ies-5005/h/zyxel-ies-5005-045.png)
Chapter 2 Hardware Installation and Connections
IES-5000 Series User’s Guide
45
Figure 23
MDF (Main Distribution Frame) Wiring
• Connect wiring to end-user equipment to the lower ports of an MDF and connect wiring
from the telephone company to the upper ports of an MDF (see the previous figure).
• Some MDFs have surge protection circuitry built in between the two banks; thus, do not
connect telephone wires from the telephone company directly to your IES-5000.
• Use a punch-down tool to seat telephone lines into MDF blocks.
2.5.3 Telco-50 Cables
Telco-50 cables are used for data and voice applications with MDFs (Main Distribution
Frame), patch panels and distribution boxes. They can also be used as extension cables. Telco-
50 cables are made up of 25 twisted-pair copper wires.
Connect a Telco-50 connector to one end of the cable (see the User’s Guide for the individual
line card for pin assignments) and connect the other end directly to an MDF; alternatively
attach RJ-11 connectors and connect directly to DSL modems or telephones.
"
The cable shown below uses a 90-degree Telco-50 connector, where the
cable extends from the side of the connector (at ninety degrees to the port).
For rear-panel splitter chassis connections using the VOP-1248G VoIP line
card, use a 180-degree Telco-50 connector (where the cable extends from the
base of the connector directly opposite the port).