Output Meters

The output meters show the signal level at the end of the DSP signal chain, 

following the Limit module. If the signal activates the limiter, the red Limit 

indicator will light over the channel experiencing an overload.

3.3.2  Function Tabs

The BEHRINGER Amp Remote window allows the user to access DSP functions via 

embedded tabs accessible near the top of the software window.

The software window includes these tabbed screens:

• 

Configuration

—controls the amplifier Mode setting for Dual Mono, 

Stereo, and other routing options, as well setting controls for output delay 

and limiting.

• 

Filter/Crossover

—offers control over adjustable hi-pass and lo-pass 

filters. In Bi-Amp 1 and Bi-Amp 2 configuration, this tab controls the 

crossover point for splitting the blended, mono input signal into separate 

high- and low-frequency mono signals for bi-amping.

• 

Parametric EQ

—controls up to 8 adjustable parametric and shelving EQs 

for each channel.

• 

Dynamic EQ

—adjusts parameters for 2 bands of level-dependent, dynamic 

equalization per channel.

• 

Setup

—manages presets and networking options.

3.3.3  Connection Status

The software displays the connection status in the top header of the main 

software window.

When the amp/software connection is active, the window heading displays the 

name of the amplifier.

3.3.4  Configuration

The Configuration tab displays two main sets of software controls:

• 

Mode

—controls the amplifier configuration. Choose between Dual Mono, 

Stereo, Bi-Amp 1, Bi-Amp 2, and Bridge configurations. Each configuration’s 

complete signal path appears in the display window, including the 

arrangement of internal DSP modules and speaker outputs.

• 

Delay/Peak Limiter

—controls settings for the Delay and Limit DSP 

modules, as well as options for channel phase, Load settings (in Ohms) for 

the limiter wattage display, Hold and Release for the Limiter, and channel 

linking. The number of Delay/Peak Limiter controls change depending on the 

amplifier Mode configuration.

Mode

Changing amplifier mode

The amplifier mode can be changed by clicking on the button for your desired 

routing option along the left-hand side of the window. When you click on a 

mode button, the software will launch a confirmation window. Click “Yes” in the 

confirmation window to launch the new amplifier mode, and the new signal path 

will appear in the display.

Mode descriptions

Dual Mono

Dual Mono mode routes each channel input, A and B, through completely 

separate parallel signal paths with independent outputs for each channel. 

Each channel may be processed with its own unique filter, equalization, delay, 

and limiter settings. The Delay and Limit modules for A and B can be linked and 

programmed with identical settings by clicking on the Channel Link button 

below the Mode window.

Stereo

BEHRINGER Amp Remote [not connected!]

BEHRINGER Amp Remote [Device: NU1000DSP!]

Stereo

Bi-Amp 1

Bi-Amp 2

Bridge

Stereo

Bi-Amp 1

Bi-Amp 2

Bridge

Stereo

Bi-Amp 1

Bi-Amp 2

Bridge

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22