![background image](/i/beko/64432/beko-et-5614-hx/h/beko-et-5614-hx-066.png)
P a r t 9 : G a s c o n v e r t i o n
Your cooker can operate both Natural Gas
and LPG. You can convert by changing the
gas source and the top burner, oven and
grill injectors. The replacement procedure
of the injectors are explained below.
Call authorized Service for gas
convertion.
Replacement of the top burner injector
Take off the burner head and burner cap before
starting this procedure. Then:
1. Remove the injector inside the top burner
with a suitable bit. Later, install the new injector
by covering the injector threads
with leakage
preventing
name failure
material.
device
spark plug
Reduced Tap Fiow
in modeis with Removal of the
control panel
Removal of the control panel
1.
Open the front door.
2.
Unscrew the two screws of the control
panel and take the control panel bottom
sheet.
3.
Release the control panel from the
two notches at the top, slightly pull it
to the bottom front and keep it free
with its cables connected.
Ignite the burner that should be adjusted,
turn the knob to the reduced position,
pull and take the knob off.
4.
With a screwdriver, make the tap
reduced flow adjustment from the
injector that is on the gas tap (only the
head is visible with the bolt shape).
It is sufficient to tight to screw
completely, in butane/propane gas.
For the natural gas, you should turn the
screw counter-clockwise
once. The normal length of a straight
flame in the reduced position
31
should be 6 - 7mm.
If the flame is higher than the desired
position, turn the screw clockwise. If its
smaller to the opposite.
For the last control of the burning of
the cooker, bring the cooker high-flame
and reduced positions and check
whether the flame is on or off.