In models with Removal of the knobs
1. Ignite the burner that should be adjusted, turn the knob to the
reduced position, pull and take the knob off.
2. With a screwdriver, make the tap reduced flow adjustment from
the injector that is on the gas tap (only the head is visible with
the bolt shape).
It is sufficient to tight to screw completely, in butane/propane gas.
For the natural gas, you should turn the screw counter-clockwise
once. The normal length of a straight flame in the reduced position
should be 6 - 7mm.
If the flame is higher than the desired position, turn the screw
clockwise.
If its smaller to the opposite. For the last control of the burning
of the cooker, bring the cooker high-flame and reduced positions
and check whether the flame is on or off.
32