![background image](/i/hotpoint-ariston/152127/hotpoint-ariston-ph-960mst/h/hotpoint-ariston-ph-960mst-025.png)
GB
25
Table 1
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Semi-Fish burner (SP)
Supply
pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
75
55
130
-
2.60
1.65
1.00
3.25
1.50
Nominal
Reduced
0.70
0.40
0.40
1.50
0.70
By-pass
1/100
(mm)
39
28
28
61
39
Nozzle
1/100
(mm)
Flow*
g/h
***
80
64
50
91
60
Flow*
l/h
110 (Y)
96 (Z)
71 (X)
133 (Z)
88
248
157
95
309
143
189
120
73
236
109
**
186
118
71
232
107
*
A 15°C e 1013,25 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
Burner and nozzle specifications
3
Nozzle
1/100
(mm)
Liquid Gas
Natural Gas
TC
S
RR
A
RR
S
A
TC
SP
PH 941 MSTB GH/HA
PH 960 MST/HA