28
Operation and settings
Camera ID: Enter the PTZ device ID. Make the same
>
ID as the PTZ Device.
Pan speed: Enter the panning speed of the PTZ
>
device in the edit box. Default value for the LG Multix
Protocol is 60 and ranges from 0 to 127.
Tilt speed: Enter the tilting speed of the PTZ device in
>
the edit box. Default value for the LG Multix Protocol
is 60 and ranges from 0 to 127.
Zoom speed: Enter the zoom speed of the PTZ device
>
to view the object close or at a distance. Default
value for the LG Multix protocol is 1 and ranges from
0 to 3.
Focus speed: Enter the focus speed of the PTZ device
>
to focus an object clearly near or far. Default value for
the LG Multix protocol is 1 and ranges from 1 to 3.
Preset tour park time: Enter the parking time.
>
Port
Baud rate: Select the desired speed of communica
-
>
tion between the IP device and the PTZ Device.
Confirm selected parameter to the baud rate of the
IP device.
Data bit: Set the number of the data bits for RS-422/
>
RS-485 communication.
Parity: Select the desired parameter. The parity bit,
>
added to the data, to perform parity check.
Stop bit: Enter the desired parameter. The stop bit,
>
added to the last of data, in asynchronous commu-
nication.
Save: Click this button to confirm the settings.
•
Preset
Preview
You can see the settings screen from the preview window.
1. Move the camera to the point you want by using the
arrow buttons.
2. Adjust the zoom, focus or iris options.
3. Set the Pan, Tilt, Zoom or Focus speed options.
4. Click the [Save] button to confirm the settings.
Pattern
You can activate the camera in a repeating pattern. The pat-
tern is programmed by recording your manual pan, tilt, and
zoom operations. The camera stores the movements you
performed in memory.