6-58
Care and Maintenance
OG
L
0 0
3. Remove the 2 screws securing the black plastic cover on the TH assembly.
4. Unplug the 2 connectors, disconnect the cable from the cable clamp located on the
bottom side of the TH assembly, and remove the TH assembly.
5. Press down slightly on the transfer/separation corotron assembly while pulling
forward to remove it.
6. Install the new transfer/separation corotron unit.
7. Reconnect the cables.
8. Reinstall the black plastic cover, securing it in place with the 2 new purple
thumbscrews. (Using the special tool may help secure the thumbscrews.)
9. Gently close the transport deck handle by turning it up (counterclockwise).
10. Close the front door.
CAUTION
!
Ensure cable connectors are secure.
Ensure the tab on the drum assembly fits into the slot on the transfer/
separation as the deck is closed.
Gently close the transport deck to prevent possible CQ defects.
Sensor Cable
Corotron Unit
Motor Cable
TH Cable Cover
Thumbscrew
Special Tool
Thumbscrew
Brown
Red
Black
Connectors
Violet
(42.5 mm)
(79mm)