Appendix A Log Descriptions

NWA3000-N Series User’s Guide

294

Device HA has skipped 

syncing %s since %s is 

%s.

A certain service has no license or the license is expired, so it 
was not synchronized from the Master. 1st %s: The object to 
be synchronized, 2ed %s: The feature name for the object to 
be synchronized, 3rd %s: unlicensed or license expired.

Device HA 

authentication type 

for VRRP group %s 

maybe wrong.

A VRRP group’s Authentication Type (Md5 or IPSec AH) 
configuration may not match between the Backup and the 
Master. %s: The name of the VRRP group.

Device HA 

authenticaton string 

of text for VRRP group 

%s maybe wrong.

A VRRP group’s Simple String (Md5) configuration may not 
match between the Backup and the Master. %s: The name of 
the VRRP group.

Device HA 

authentication string 

of AH for VRRP group 

%s maybe wrong.

A VRRP group’s AH String (IPSec AH) configuration may not 
match between the Backup and the Master. %s: The name of 
the VRRP group.

Retrying to update %s 

for %s. Retry: %d.

An update failed. Retrying to update the failed object again. 
1st %s: The object to be synchronized, 2ed %s: The feature 
name for the object to be synchronized,  %d: the retry count.

Recovring to Backup 

original state for %s 

has failed.

An update failed. The device will try to recover the failed 
update feature to the original state before Device HA 
synchronizes the specified object.

Recovering to Backup 

original state for %s 

has succeeded.

Recovery succeeded when an update for the specified object 
failed.

One of VRRP groups has 

became avtive. Device 

HA Sync has aborted 

from Master %s.

%s: IP or FQDN of Master

Master configuration 

file does not exist. 

Skip updating ZySH 

Startup 

Configuration.

System internal error: 

%s. Skip updating %s.

1st %s: error string, 2ed %s: the syncing object

Master configuration 

file is empty. Skip 

updating ZySH Startup 

Configuration.

Device HA Sync has 

failed when syncing %s 

for %s due to 

transmission timeout.

1st %s: the syncing object, 2ed %s: the feature name for the 
syncing object

VRRP interface %s has 

been shutdown.

%s: The name of the VRRP interface.

Table 102   

Device HA Logs (continued)

LOG MESSAGE

DESCRIPTION

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
Оглавление инструкции

Document Outline