DGS-3710 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
125
Parameters
trap
- Specifies the trap state.
log
- Specifies the log state.
none
- Specifies neither attack_detected nor attack_cleared is trapped or logged.
attack_detected
- Specifies events will be logged or trapped when the BPDU attacks is detected.
attack_cleared
- Specifies events will be logged or trapped when the BPDU attacks is cleared.
both
- Specifies the events of attack_detected and attack_cleared shall be trapped or logged.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the BPDU protection trap state as both for the entire switch:
DGS-3710-12C:admin#config bpdu_protection trap both
Command: config bpdu_protection trap both
Success.
DGS-3710-12C:admin#
10-4
enable bpdu_protection
Description
This command is used to enable BPDU protection globally for the entire switch.
Format
enable bpdu_protection
Parameters
None.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To enable BPDU protection for the entire switch:
DGS-3710-12C:admin#enable bpdu_protection
Command: enable bpdu_protection
Success.
DGS-3710-12C:admin#