![background image](/i/d-link/144853/d-link-dgs-3710-12c/h/d-link-dgs-3710-12c-150.png)
DGS-3710 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
146
DGS-3710-12C:admin#show cfm fault
Command: show cfm fault
MD Name MA Name MEPID Status
----------- ---------- --------- -----------------------
op_domain op1 1 Cross-connect CCM Received
DGS-3710-12C:admin#
12-18
show cfm port
Description
This command is used to display MEPs and MIPs created on a port.
Format
show cfm port <port> {level <int 0-7> | direction [inward | outward] | vlanid <vlanid 1-4094>}
Parameters
<port>
- Specifies the port number.
level
- (Optional) Specifies the maintenance domain level. If not specified, all levels are shown.
<int 0-7>
- Specifies the value between 0 and 7.
direction
- (Optional) Specifies the MEP direction.
inward
- Specifies inward facing MEP.
outward
- Specifies outward facing MEP.
vlanid
- (Optional) Specifies the VLAN identifier. If not specified, all VLANs are displayed.
<vlanid 1-4094>
- Specifies the VLAN ID between 1 and 4094.
Restrictions
None.
Example
To display a CFM port:
DGS-3710-12C:admin#show cfm port 1
Command: show cfm port 1
MAC Address: 00-05-78-82-32-01
MD Name MA Name MEPID Level Direction VID
----------- ---------- ------- ------- --------- ---
op_domain op1 1 2 inward 2
cust_domain cust1 8 4 inward 2
serv_domain serv2 MIP 3 2
DGS-3710-12C:admin#