DGS-3710 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
15
2-9
show environment
Description
This command is used to display the device internal and external power and internal temperature
status.
Format
show environment
Parameters
None.
Restrictions
None.
Example
To display the switch hardware status:
DGS-3710-12C:admin#show environment
Command: show environment
Left Fan 1 : Speed 0
Left Fan 2 : Speed 0
Left Fan 3 : Reserved
Current Temperature(Celsius) : 28
Fan High Temperature Threshold(Celsius) : 51
Fan Low Temperature Threshold(Celsius) : 40
High Warning Temperature Threshold(Celsius) : 70
Low Warning Temperature Threshold(Celsius) : 5
CTRL+C
ESC
q
Quit
SPACE
n
Next Page
p
Previous Page
r
Refresh
2-10
config temperature
Description
This command is used to configure the warning trap or log state of the system internal temperature.
Format
config temperature [trap | log] state [enable | disable]
Parameters
trap
-
Specifies to configure the warning temperature trap.
log
-
Specifies to configure the warning temperature log.
state
-
Enable or disable either the trap or log state for a warning temperature event. The default