DGS-3710 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
718
portID: port ID.
deviceClass: LLDP-MED device type.
Event description: Incompatible LLDP-MED TLV set detected
Log Message: Incompatible LLDP-MED TLV set detected ( on port <
portNum >, chassis id: < chassisType>, <chassisID>, port id: <
portType>, <portID>, device class: <deviceClass>)
Parameters description:
portNum: The port number.
chassisType: chassis ID subtype.
Value list:
1. chassisComponent(1)
2. interfaceAlias(2)
3. portComponent(3)
4. macAddress(4)
5. networkAddress(5)
6. interfaceName(6)
7. local(7)
chassisID: chassis ID.
portType: port ID subtype.
Value list:
1. interfaceAlias(1)
2. portComponent(2)
3. macAddress(3)
4. networkAddress(4)
5. interfaceName(5)
6. agentCircuitId(6)
7. local(7)
portID: port ID.
deviceClass: LLDP-MED device type.
Notice
CFM
Event description: Cross-connect is detected
Log Message: CFM cross-connect. VLAN:<vlanid>, Local(MD
Level:<mdlevel>, Port <portNum>, Direction:<mepdirection>)
Remote(MEPID:<mepid>, MAC:<macaddr>)
Parameters description:
vlanid: Represents VLAN identifier of the MEP.
mdlevel: Represents MD level of the MEP.
portNum: Represents the logical port number of the MEP.
mepdirection: Can be "inward" or "outward".
mepid: Represents the MEPID of the MEP.
macaddr: Represents the MAC address of the MEP.
Critical
Event description: CFM error ccm
Log Message: CFM error ccm. MD Level:<mdlevel>, VLAN:<vlanid>,
Local(Port <[unitID:]portNum>, Direction:<mepdirection>)
Remote(MEPID:<mepid>, MAC:<macaddr>)
Parameters description:
vlanid: Represents VLAN identifier of the MEP.
mdlevel: Represents MD level of the MEP.
unitID: Represents the ID of the device in the stacking system.
portNum: Represents logical port number of the MEP.
mepdirection: Can be "inward" or "outward".
mepid: Represents MEPID of the MEP.
macaddr: Represents MAC address of the MEP.
Warning
Event description: CFM remote down
Log Message: CFM remote down. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port <portNum>, Direction:<mepdirection>)
Parameters description:
vlanid: Represents VLAN identifier of the MEP.
mdlevel: Represents MD level of the MEP.
unitID: Represents the ID of the device in the stacking system.
portNum: Represents logical port number of the MEP.
mepdirection: Can be "inward" or "outward".
Warning
Event description: CFM remote MAC error
Log Message: CFM remote MAC error. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port <portNum>, Direction:<mepdirection>)
Parameters description:
vlanid: Represents VLAN identifier of the MEP.
mdlevel: Represents MD level of the MEP.
portNum: Represents the logical port number of the MEP.
mepdirection: Can be "inward" or "outward".
Warning
Event description: Remote MEP detects CFM defects
Informational