DGS-3710 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
494
error
- (Optional) Specifies severity level 3.
warning
- (Optional) Specifies severity level 4.
notice
- (Optional) Specifies severity level 5.
informational
- (Optional) Specifies severity level 6.
debug
- (Optional) Specifies severity level 7.
<level_list 0-7>
- (Optional) Specifies a list of severity levels to be displayed. If more than one
severty level, separate them by comma. The level numbers are from 0 to 7.
module
- Specifies the modules to be displayed. The module can be obtained by the show
log_software_module command. Use commas to separate multiple modules.
<module_list>
- Specifies the modules to be displayed.
Note:
If no parameter is specified, all history log entries will be displayed.
Restrictions
None.
Example
To display the switch history log:
DGS-3710-12C:admin#show log index 1-5
Command: show log index 1-5
Index Date Time Level Log Text
----- ---------- -------- ------- --------------------------------------------
5 2010-05-06 11:27:15 INFO(6) Port 4 link up, 100Mbps FULL duplex
4 2010-05-06 10:30:10 INFO(6) Successful login through Console (Username:
Anonymous)
3 2010-05-06 08:59:59 INFO(6) Port 24 link up, 100Mbps FULL duplex
2 2010-05-06 08:59:58 CRIT(2) System cold start
1 2010-05-06 08:59:58 ERRO(3) System has reset without management command
DGS-3710-12C:admin#
47-12
show log_save_timing
Description
This command is used to display the method to save log.
Format
show log_save_log_timing
Parameters
None.