DGS-3710 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
144
Restrictions
None.
Example
To display the CFM state for ports 3 to 6:
DGS-3710-12C:admin#show cfm ports 3-6
Command: show cfm ports 3-6
Port State
----- -------
3 Enabled
4 Enabled
5 Enabled
6 Enabled
DGS-3710-12C:admin#
12-16
show cfm
Description
This command is used to display the CFM configuration.
Format
show cfm {[md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22> | ma_index
<uint 1-4294967295>] {mepid <int 1-8191>}} | mepname <string 32>]}
Parameters
md
- (Optional) Specifies the maintenance domain name.
<string 22>
- Specifies the maintenance domain name. The maximum length is 22
characters.
md_index
- Specifies the maintenance domain index.
<uint 1-4294967295>
- Enter the maintenance domain index value here. This value must
be between 1 and 4294967295.
ma
- (Optional) Specifies the maintenance association name.
<string 22>
- Specifies the maintenance association name. The maximum length is 22
characters.
ma_index
- Specifies the maintenance association index.
<uint 1-4294967295>
- Enter the maintenance association index value here. This value
must be between 1 and 4294967295.
mepid
- (Optional) Specifies the MEPID.
<int 1-8191>
- Specifies the MEP MEPID between 1 and 8191.
mepname
- (Optional) Specifies the MEP name.
<string 32>
- Specifies the MEP name. The maximum length is 32 characters.
Restrictions
None.